7. Replacing the humidity sensor

1
Perform steps
1
2
Disconnect the humidity sensor cord from the cord clip, then cut the binding bands (2) inside the electrical
component box, and disconnect the humidity sensor connector.
Humidity sensor connector (HU)
3
Remove the sensor installation bracket (2 screws).
Disconnect the humidity sensor cord from the cord clips (4 locations).
Room temperature
sensor
Sensor installation
bracket
Screws
4
Remove the screw (1) from the sensor cover, then remove the sensor cover from the sensor installation
bracket.
Next, open the sensor cover tabs (2) and remove the humidity sensor PCB.
Sensor installation
bracket
3
from "Replacing the fan motor."
Screw
Sensor cover
Cord clips
Humidity sensor
PCB