( 5 )
RR (Reset restart)
Input of an external reset-restart signal (CC4 of the DIGITAL terminal: External VD input) permits one screen of
information to be output at an arbitrary timing.
(5. 1)
Long Term Exposure
When sufficient sensitivity is not obtained under normal operating conditions or capturing the trail of a moving object
is desired, the reset-restart function allows high-sensitivity images by extending the exposure time. To achieve this,
please input (from an external source) a VD signal that has an expanded VD pulse and VD pulse interval.
(5. 2)
Input Timing Chart Example
External HD IN
External VD IN
(Internal VD)
Exposure period
RGB data
(video interval image)
FVAL
LVAL,
DVAL
V reset
About 1H
Exposure period
1 frame
1 frame= 796H (Partial scanning OFF)
Note:
External VD interval: more than 1 frame
580H (Partial scanning 40fps)
553H (Partial scanning 42fps)
465H (Partial scanning 50fps)
387H (Partial scanning 60fps)
332H (Partial scanning 70fps)
290H (Partial scanning 80fps)
258H (Partial scanning 90fps)
V reset
About 1H
Exposure period
31