When Desiring To See Automatic Sequential Conversion Screen - Samsung SDM-090P User Manual

Digital multiplexer
Hide thumbs Also See for SDM-090P:
Table of Contents

Advertisement

SDM-090(P)
Digital Multiplexer

When desiring to see automatic sequential conversion screen

The automatic sequential conversion mode operates in the LIVE screen status
and consists of the following 2 cases:
The FULL screen is converted if pressing the "SEQUENCE" button in the FULL
screen status. The screen on the bottom right side is converted if pressing the
"SEQUENCE" button in the 4-division screen status. The LED of the
"SEQUENCE" button turns on .
The conversion time in the automatic sequential conversion mode is set in the
"SEQUENCE.." of the "2, MON OUT SET" in case of the PRPGRAM mode for
the FULL screen and the time to set up is 00sec ~ 30sec. The screen set to
00sec is skipped. The screen on the right bottom is switched in the interval of a
second for the 4-division screen.
Method to release
- Press the "SEQUENCE" button once again. In this case the LED turns off.
And then it stops on the screen currently seen.
The "SEQUENCE" button does not operate in the following cases:
- In replay mode or TRIPLEX mode
- In the division screen mode other than 4-division screen
- In setting of program mode
- In displaying ALARM LIST on screen
- During ZOOM operation
- During ALARM operation