Samsung SRP-350PG - SRP 350 B/W Direct Thermal Printer Service Manual page 66

Thermal receipt printer srp-350 ver.2 series
Table of Contents

Advertisement

Command
DLE ENQ n
[Name]
Real-time request to printer.
[Format]
ASCII
Hex
Decimal
[Range]
1 ≤n ≤2
[Description]
Recovers from an error and restart printing from the line where the error occurred.
ESC FF
[Name]
Print data in page mode.
[Format]
ASCII
Hex
Decimal
[Description]
In page mode, prints all buffered data in the printing area collectively.
ESC SP n
[Name]
Set right-side character spacing.
[Format]
ASCII
Hex
Decimal
[Range]
0 ≤n ≤255
[Description]
Sets the character spacing for the right side of the character to
[n ×horizontal or vertical motion units].
ESC ! n
[Name]
Select print modes.
[Format]
ASCII
Hex
Decimal
[Range]
0 ≤n ≤255
[Description]
Selects print mode(s) using n as follows.
Bit
Off/On
Hex
0
Off
00
On
01
1,2
-
-
3
Off
00
On
08
4
Off
00
On
10
5
Off
00
On
20
6
-
-
7
Off
00
On
80
ESC $ nL nH
[Name]
Set absolute print position.
[Format]
ASCII
Hex
Decimal
[Range]
0 ≤n ≤255
0 ≤n ≤255
[Description]
Set the distance from the beginning of the line to the position at which subsequent characters are to be
printed.
* The distance from the beginning of the line to the print position is
[(nL + nH ×256) ×(vertical or horizontal notion unit)] inches.
Samsung Electro-Mechanics
DLE
ENQ
n
10
05
n
16
5
n
ESC
FF
1B
0C
27
12
ESC
SP
n
1B
20
n
27
32
n
ESC
!
n
1B
21
n
27
33
n
Decimal Function
0
Character font(12 ×24) selected.
1
Character font(9 ×17) selected.
-
Undefined.
0
Emphasized mode not selected.
8
Emphasized mode selected.
0
Double-height mode not selected.
16
Double-height mode selected.
0
Double-width mode not selected.
32
Double-width mode selected.
-
Undefined.
0
Underline mode not selected.
128
Underline mode selected.
ESC
$
nL
n
1B
24
nL
n
27
36
nL
n
8-3

Hide quick links: