Yamaha 02R96 Owner's Manual page 226

Digital mixing console version 2.0
Hide thumbs Also See for 02R96:
Table of Contents

Advertisement

226
Chapter 19—Remote Control
Select one of two buttons located to the right of trigger signal parameters
4
INPUT 1 & 2 to specify how the incoming trigger signals will be detected.
: When the switch is grounded (Low), the trigger signal is active and the selected param-
eter changes.
: When the GPI Input goes High (open), the trigger signal is active and the selected
parameter changes.
You can execute functions assigned to the MONITOR section buttons and User Defined
Keys, and turn channels on and off. See "GPI Trigger Source & Target List" on page 253 for
a complete list of assignable functions.
Note: "xxx UNLATCH" means that the assigned function is enabled only while the incoming
trigger signal is active. For example, if CH1 ON is selected, the channel on/off status changes
each time the trigger signal is detected. If CH1 ON UNLATCH is selected, Channel 1 turns
on only while the trigger signal is active.
At this point, when the 02R96 receives the trigger signal at the CONTROL connector, the
selected parameter changes.
Tip: Refer to the page 253 for a complete list of assignable parameters.
TALKBACK - SMALL: Functions the same as the MONITOR section buttons.
SR xxx: Functions the same as the SURROUND buttons in the MONITOR section.
CR xxx: Functions the same as the CONTROL ROOM buttons in the MONITOR section.
SM xxx: Functions the same as the STUDIO buttons in the MONITOR section.
xxx UNLATCH: The assigned function is enabled only while the incoming trigger signal
is active.
xxx ON: The corresponding channels turn on or off each time the incoming trigger signal
becomes active.
xxx ON UNLATCH: The corresponding channels turn on only while the incoming trig-
ger signal is active.
UDEFxxx: Functions the same as the USER DEFINED KEYS.
To select parameters or controls as trigger signal sources, use the cursor but-
5
tons to select an output from OUTPUT 1–8, then select trigger signal param-
eters as you would for the INPUT section.
See "GPI Trigger Source & Target List" on page 253 for a complete list of assignable param-
eters.
02R96 Version 2—Owner's Manual
Trigger =
Input signals from
the CONTROL con-
nector
Executes the function.
Trigger =
Input signals from
the CONTROL con-
nector
Executes the function.
Executes the function.
Executes the function.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

O2r 96 version 2

Table of Contents