Errors or possible errors detected in the operand field of a BSS, EQU, or ORG instruc-
tion are printed or typed with the present setting of the memory allocation register,
the card type, and the error code. The error codes are:
U - an undefined symbol
A - a possible error in an address
4.
Messages:
NO END CARD
MULTIPLE
SYMBOLS
END OF PASSl
SYMBOL TABLE
OVERFLOW
Indicates the symbolic deck does not terminate with an end
' card. Assembly continues to the normal end of job.
Indicates a multiply-defined symbol in the symbol or operand
fields.
Signifies the end of the assembly program pass 1 run.
Messages (and action to be taken) are the same as for the
General Assembly Program 0 run.
5.
For all other errors, repeat previous load procedure described for pass
1.
GENERAL ASSEMBLY PROGRAM PASS 2
The procedure for pass 2 is as follows:
1.
The input for pass 2 is the output from pass 0 and pass
1.
If
console switch 4 is down,
set up the input deck as follows:
Assembly program pass 2 binary deck followed by the output of pass 1 followed by the
rearranged output from pass 0. (See Figure A-2.)
2.
Load cards.
3.
Messages:
ERRORS
NO ERRORS
END OF PASS 2
SYMBOL LOST
Indicates presence of a real or suspected source program
error.
Indicates no errors were found.
Signifies the end of the pass 2 run.
Is typed with the setting of the memory allocation register
and the symbol in question when a symbol appearing in the
symbol field cannot be found in the symbol table. This is
caused by a machine error and may necessitate a reassembly.
Action required for SYMBOL LOST:
a .
List all output from pass
O.