Komatsu ecot3 Operation And Maintenance Manual page 113

Hide thumbs Also See for ecot3:
Table of Contents

Advertisement

DETAILED CONTROLS AND GAUGES
DETAILED CONTROLS AND GAUGES
2. On the 2-Way Attachment Select Menu, select one of the two
set values for the oil flow, then press switch F6.
The default values for the oil flow setting are both set to 430
liters/min, as shown in the illustration on the right.
To change the oil flow setting, follow the procedure given in
"Adjusting Economy Mode (PAGE 3-69)".
The present oil flow set for ATT mode is marked with ATT in
front of the item name as shown in the illustration on the
right.
If No 2-Way Attachment is selected, it becomes impossible
to select the attachment mode on the working mode
selection screen.
On the working mode selection screen, it is not possible to select
No 2-Way Attachment.
On the 2-Way Attachment Select Menu screen and 2-way
attachment select menu, it is possible to carry out the following
operations with switches F3 to F6.
F3: Moves to next item (1 line down).
F4: Moves to previous item (1 line up).
F5: Returns to previous screen.
F6: Switches to setting screen for selected item.