DETAILED CONTROLS AND GAUGES
DETAILED CONTROLS AND GAUGES
On the Breaker Select Menu and Breaker Oil Flow Setting
screen, it is possible to carry out the following operations with
switches F3 to F6.
F3: Moves to next item (1 line down).
F4: Moves to previous item (1 line up).
F5: Returns to previous screen.
F6: Switches to setting screen for selected item.
3. On the Breaker Oil Flow Setting screen, change the set oil flow.
After using switches F3 or F4 to change to a suitable oil flow,
press switch F6 to accept the change in the oil flow and
return to the previous screen.
When switch F5 is pressed, no change is made in the oil flow
and the screen returns to the previous screen.
(X): Present oil flow setting
(Y): Min. adjusted oil flow
(Z): Max. adjusted oil flow
3 - 52
OPERATION
OPERATION

Advertisement