SERVICE & INSTALLATION MENU
5 Press " " or " " to select "Save" and press "OK" to change
password.
Select "Not Save", the screen returns to Step3.
Press " ", the screen returns to Step2.
Change Password
Change Password
Enter Password
Enter Password
Save the new password?
6
6
8
Save
OK
Check
Confirm
Check
OK
OK
6 Press "OK", the screen returns to Step2.
Change Password
Change Password
Enter Password
Enter Password
Password Saved.
6
6
8
OK
OK
OK
Confirm
Check
Check

Set Password Input Effective Time
1 Select "Service Menu" on the Service & Installation screen
and press "OK".
2 Select "Password Setting" and press "OK".
3 Select "Effective Time"and press "OK".
4 Press " " or " " to select the setting item and press "OK" to
confirm the setting. The item changes as follows:
"Everytime" ↔ "10 min" ↔ "30 min" ↔ "60 min" ↔ "120 min".
Press " " and it returns to Step3.
Password Input Effective Time
Everytime
10 min.
30 min.
60 min.
120 min.
OK
Select
?
N O T E
The default password is "0000", and the supervisor code is "5567".
If you forget the password, use the supervisor code to change the
password.
The supervisor code can't be changed.
For two remote controllers, the passwords are not synchronized
automatically. For each remote controller, the password needs to be
set individually.
72
PMML0565 rev.0 - 09/2021
6 8 2 4
2
2
4
4
Not Save
2
2
4
4
OK

6.2.3 Hotel Mode Setting

This setting enables or disables the hotel mode.
1 Select "Service Menu" on the Service & Installation screen
and press "OK".
2 Select "Hotel Mode" and press "OK".
3 Press " " or " " to select enabled setting.
4 After selecting, press "OK".
5 Select "Yes" and press "OK" to confirm the settings and
OK
OK
display the completion screen.
6 If you select "Cancel", the screen returns to Step3.
?
N O T E
Back
Back
Back
Refer to "Hotel Mode Setting" in "9 Hotel Mode Setting".

6.2.4 Power Saving Details Setting

This function provides the details for setting the power savings
function.
For the "Mode", select one item from each of the following
settings, outdoor unit capacity control, indoor unit rotation
control, and intermittent control.
OK
OK
OK
?
N O T E
Go to Power Savings Setting from Function Menu. Also refer to "Power
Savings Setting" in "5.3.1 Power Savings Mode Setting" for details.
Back
Back
Back
Item
Capacity Control
Rotation Control
Intermittent Control
Reset Default

Outdoor Capacity Control Setting
Item
Control Method
Power Savings Low
Back
(Med/High)
Change Level
Function
Suppress the heating and cooling capacity of
the indoor unit. Set control mode and power
savings level with its corresponding value.
Interlock with indoor units of the same outdoor
unit system and switch to FAN operation in
sequence. Set control mode and fan mode time.
Cooling/heating mode and fan mode are
repeated at regular intervals. Set power savings
level.
Initialize the power saving details settings.
Description
The "Peak Cut Control" reduces the power
consumption range when it exceeds the
value of the power setting. On the basis of
the current air conditioning capacity, the
"Moderate Control" is used to moderate the air
conditioning capacity as well as the peak.
Assign the corresponding capacity control
values to the low, medium, and high power
savings levels.
The power saving details setting can change
the power savings levels.