Main code
Sub code
06
01
PSPS operation check
The separation pawl is turned on/off 30 times in the following sequence.
PSPS
07
01
Warm-up time display and aging
After execution of the simulation, warm-up is started, and the swarm-up time is displayed every second on the
copy quantity display. When warm-up is completed (RPL ON), count adding of the display is stopped.
Press the CA key to clear warm-up time display, set the copy quantity and press the PRINT button to make the set
number of copies repeatedly.
04
Warm-up omitting
After completion of the simulation, the machine goes to the ready state. (RPL ON)
06
Intermittent aging
After execution of the simulation, the machine starts warm-up. After completion of warm-up, press the CA key to
clear warm-up time display, set the copy quantity and press the PRINT button to make the set number of copies
repeatedly.
After the interval time (2 min) from completion of making the set number of copies, the machine resumes copying.
08
Warm-up time display
Aging function is deleted from SIM 7-1.
08
01
DVBIAS check
The developing bias is turned on for 30 sec.
02
MTHV (main, transfer), grid check (ME)
The main/transfer charger is turned on for 30 sec.
For the grid bias, the ME value is outputted.
03
MTHV (main, transfer), grid check (PE)
The main/transfer charger is turned on for 30 sec.
For the grid bias, the PE value is outputted.
04
MTHV (main, transfer), grid check (T/S)
The main/transfer charger is turned on for 30 sec.
For the grid bias, the T/S value is outputted.
07
SHV (separation) check
The separation charger is turned on for 30 sec.
10
Toner motor aging
The toner motor is turned on.
14
Cancel of troubles (except for U2)
Troubles (except for U2) are canceled and the simulation is also canceled automatically.
15
Cancel of waste toner full (è blinks)
The waste toner full indication (è blinks) is canceled, and the simulation is also canceled automatically.
16
U2 trouble cancel
U2 trouble is canceled, and the simulation is automatically canceled.
20
(Note)
Maintenance counter clear
The maintenance counter is cleared and the maintenance counter value is displayed on the copy quantity display.
("000" is displayed because the counter value is cleared.)
(Note) Cleared by entering the sub code "01."