A. Use of special measurement tools
Tool: UKOGE0043CS01 (Digital multi meter)
Electrode sheet (UKOG-0110FCZZ)
Adjustment
Adjustment
Sim
output
TC current
08-02
Standard (A)
–750 ±5V
MC grid
Photo (b)
44-11
–500 ±5V
voltage
TS (c)
–650 ±5V
DV bias voltage
08-01
Electrode sheet harness (DHAI-0304FCZZ)
Orange
(Microswitch)
(QSW-M0118FCZZ) PHOG-0007FCZZ
QTIPH0017FCZZ
(Wiring of sectionA)
Orange
300KΩ x 2
White
(VRN-RT2EK304F)
C. Transfer charger output check
1) Transfer charger current adjustment
1 Remove the developing unit, the transfer/separation charger unit,
and the main charger unit from the copier.
2 Remove the process unit from the copier.
When removing (attaching) the process unit from (to) the copier,
do not hold the toner transport pipe.
3 Remove the photoconductor drum from the process unit, and at-
tach the electrode sheet by using rubber ring and tape.
4 Attach the photoconductor drum with the electrode sheet attached
to it to the process unit.
UKOG-0110FCZZ
F/R
Tester
range
difference
range
–41.0
7.0 µA
DC1000 µA
±4.0 µA
DC1000V
–200±5V
DC1000V
Orange
Green
(QCLIZ0005FCZZ)
A
Blue
Blue
(QCLIZ0006FCZZ)
Black
Black
White
(QCLIZ0010FCZZ)
White
Yellow
(QCLIZ0004FCZZ)
Red
Red
(QCLIZ0002FCZZ)
Blue
Black
5 Attach the process unit to the copier. (Attach so that the electrode
sheet lead wire extends from the developing unit side.)
6 Clean the transfer charger wire, and attach the transfer/separation
charger unit to the copier.
(Do not install the main charger unit.)
7 Connect the electrode sheet and the digital multi meter (or an
ammeter). Manually turn on the door switch.
Yellow clip
Black clip
Copier chassis
(Uncoated section)
2
20
2 00
Digital multi meter
(UKOGE0043FC01)
(Note) Check that the black clip is firmly grounded to the chassis.
When the UKOGE0043CS01 is used:
Control 1: Set to "2" of DCmA.
Red clip: Connect to
Blue clip: Connect to -.
When a DC ammeter is used:
Red clip: Connect to - of the DC ammeter.
Blue clip: Connect to
8 Transfer charger output current check and adjustment
a. Turn on the main switch and execute simulation 8-02. (MTHV
is turned on for 30 sec.)
b. Adjust VR102 (MTHV output adjustment control) so that the
output current of MTHV is –41 ±4.0 µA.
7 – 21
Green clip
Orange
White
White
Black
Blue Red
(DCmA)
Blue clip
Red clip
.
of the DC ammeter.
Orange
(Microswitch)