Huawei 01075345 User Manual page 98

Hide thumbs Also See for 01075345:
Table of Contents

Advertisement

SUN2000-(2KTL-6KTL)-L1
User Manual
Alarm
Alarm Name
ID
2011
String Reversed
2021
AFCI Check
Failure
2032
Grid Failure
Issue 10 (2023-02-13)
Alarm
Possible Causes
Severity
Major
The PV string is reversely
connected.
Cause ID = 1, 2
● 1: PV1 is reversely
connected.
● 2: PV2 is reversely
connected.
Major
The AFCI check fails.
Cause ID = 1, 2
● 1: The AFCI check circuit
is abnormal.
● 2: The AFCI circuit is
faulty.
Major
Cause ID = 1
● The power grid
experiences an outage.
● The AC circuit is
disconnected or the AC
circuit breaker is OFF.
Copyright © Huawei Technologies Co., Ltd.
8 System Maintenance
Troubleshooting
Check whether the PV
string is reversely
connected to the SUN2000.
If yes, wait until the PV
string current decreases
below 0.5 A, set DC switch
to OFF, and adjust the PV
string polarity.
Turn off the AC output
switch and DC input switch,
and then turn them on
after 5 minutes. If the fault
persists, contact your
dealer or Huawei technical
support.
1. Check the AC voltage.
2. Check whether the AC
circuit is disconnected or
the AC circuit breaker is
OFF.