SUN2000-(2KTL-6KTL)-L1
User Manual
Figure 7-11 Apparent power control
Table 7-2 Apparent power
Parameter
Maximum apparent
power (kVA)
Maximum active power
(kW)
7.2.1.3 Battery Control
Prerequisites
The screenshots in this chapter are taken in the SUN2000 3.2.00.011 App. The App
is being updated. The actual screens may vary.
Function
When the inverter connects to a battery, add the battery and set battery
parameters.
Issue 10 (2023-02-13)
NO TE
The lower threshold for the maximum apparent power is the maximum active power. To
lower the maximum apparent power, lower the maximum active power first.
Copyright © Huawei Technologies Co., Ltd.
Description
Specifies the output
upper threshold for the
maximum apparent
power to adapt to the
capacity requirements of
standard and customized
inverters.
Specifies the output
upper threshold for the
maximum active power
to adapt to different
market requirements.
7 Man-Machine Interaction
Value Range
[Maximum active power,
S
]
max
[0.1, P
]
max
79