    Tab le of c ont e nts Notes on the instruction manual ......................4 Safety ..............................4 Intended use ............................4 Environment ............................5 ABB devices ..........................5 Product description ..........................6 Device type ..........................6 Control elements........................7 Terminal description ........................8 Lock type and connection ......................
  • Page 3 Table of contents 8.1.21 Viewing the version....................... 45 8.1.22 Viewing the serial number ..................... 46 Configure the settings on "Smart Access Point" ................ 47 8.2.1 Adding mini outdoor station ....................47 8.2.2 Configure the settings ......................48 Card management ........................55 Restoring to factory default.......................
  • Page 4: Notes On The Instruction Manual

    Please keep this manual in a safe place. If you pass the device on, also pass on this manual along with it. ABB accepts no liability for any failure to observe the instructions in this manual. Safety...
  • Page 5: Environment

    ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal. Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company.
  • Page 6: Product Description

    Product description Product description Device type Size (HxWxD) Article Product ID Product name Colour number Unit: mm H81313P1-A 2TMA130010A0001 Mini video outdoor station, Aluminum 99 x 168 x 26 1 button, ID, SM alloy H81313P2-A 2TMA130010A0004 Mini video outdoor station, Aluminum 99 x 168 x 26 2 buttons, ID, SM...
  • Page 7: Control Elements

    Product description Control elements Description Ring indicator Indicator flashes slowly: ringing Indicator flashes quickly: busy line Call indicator Unlock indicator Speaker and microphone integration Call button Label field Integrated ID card reader Product manual 2TMD041900D0015 │7...
  • Page 8: Terminal Description

    Product description Terminal description EXIT AGND LOCK NC COM NO GND DC+ Description Connector for the sensor used for door status detection Connector for exit button Plug-in clamps (LOCK...AGND) for door opener Plug-in clamps (COM...NC...NO) for floating output Plug-in clamps (DC+...GND) for standalone power supply LAN (PoE) Product manual 2TMD041900D0015 │8...
  • Page 9: Lock Type And Connection

    Product description Lock type and connection Lock type Operation type Voltage Wiring type Electrical strike ⎓ Power on to open Type A/B 12 V lock, 12V Electrical strike ⎓ Power on to open Type B 24 V lock, 24V Electrical rim Power on to open ⎓...
  • Page 10: Technical Data

    Technical data Technical data Designation Value Rating voltage ⎓ 24 V Operating voltage range ⎓ 20-27 V ⎓ 27 V , 310 mA Rating current ⎓ 24 V , 350 mA Operating temperature -40 °C…+55 °C 99 mm x 168 mm × 26 mm (H8131.P.-.) Product dimensions 105 mm x 180 mm ×...
  • Page 11: Mounting/Installation

    Mounting/Installation Mounting/Installation Warning Electric voltage! Dangerous currents flow through the body when coming into direct or indirect contact with live components. This can result in electric shock, burns or even death. – Disconnect the mains power supply prior to installation and/or disassembly! –...
  • Page 12: Mounting

    Mounting/Installation Mounting 7.2.1 Preparation Use gloves to protect yourself against cuts. 7.2.2 Installation height 1.5 m 5 feet Product manual 2TMD041900D0015 │12...
  • Page 13: Installation Situation

    Mounting/Installation 7.2.3 Installation situation Note The following installation situations must be avoided without fail to ensure picture quality: Direct light ■ Direct sunlight ■ Extremely bright picture background ■ Highly reflective walls on the opposite side of the door station ■...
  • Page 14: Surface-Mounted Installation

    Mounting/Installation 7.2.4 Surface-mounted installation Product dimension 99 mm 26.5 mm 78 mm 62 mm 60 mm Surface-mounted on the wall Mount ing screw x 4 ⌀ Screw shaf t: S cre w length: ≥ 25 mm Product manual 2TMD041900D0015 │14...
  • Page 15 Mounting/Installation Surface-mounted on the box (e.g. VDE box) Mounting screw x 4 ⌀ S crew shaft : S cre w le ngth: 25 mm ≥ Product manual 2TMD041900D0015 │15...
  • Page 16: Flush-Mounted Installation

    Mounting/Installation 7.2.5 Flush-mounted installation Product dimension 99 mm 45 mm 105 mm 53 mm 99 mm Flush-mounted with pre-installation box Mounting scre w x 4 ⌀ Screw sh aft : S cre w length: ≥ 25 mm Product manual 2TMD041900D0015 │16...
  • Page 17: Cavity Wall Installation

    Mounting/Installation 7.2.6 Cavity wall installation Product dimension 92 mm 105 mm 43 mm 90 mm 97 mm Mounting Mounting screw x 4 ⌀ Screw shaft : Screw le ngth: ≥ 2 5 mm Product manual 2TMD041900D0015 │17...
  • Page 18: Replacing The Nameplate

    Mounting/Installation 7.2.7 Replacing the nameplate Product manual 2TMD041900D0015 │18...
  • Page 19: Commissioning

    Commissioning Commissioning Configure the settings on indoor station 8.1.1 Enter engineering mode of outdoor station Note The mini outdoor station must be on the same network as the indoor station. Unlock indicator Fi rst pushbutton P ushbutton m odule Please follow the steps below, Power up the mini outdoor station, the three indicators light up green.
  • Page 20: Enter Outdoor Station Through An Indoor Station

    Commissioning 8.1.2 Enter outdoor station through an indoor station On the extra screen of indoor station, click "System" to access the corresponding screen. On the "System settings" screen, click "Engineering settings", enter the engineering password to access the corresponding screen. Product manual 2TMD041900D0015 │20...
  • Page 21 Commissioning On the "Engineering settings" screen, tap "Outdoor station settings" to access the corresponding screen. Product manual 2TMD041900D0015 │21...
  • Page 22: Device Type Settings

    Commissioning 8.1.3 Device type settings 1. Device type = OS (outdoor station) Please follow the steps below: [1] On the "Outdoor station settings" screen, select "OS" from the drop-down list. [2] Enter the block number (1…999). [3] Enter the device number (1…64). [4] Tap "...
  • Page 23 Commissioning 2. Device type = 2nd OS (2nd confirmed outdoor station) Location of IP gateway = Internal In this case, the 2nd OS is connected to the router in the apartment (see diagram below). Please follow the steps below: [1] On the "Outdoor station settings" screen, select "2nd OS" from the drop-down list. [2] Select "Internal"...
  • Page 24 Commissioning Location of IP gateway = External In this case, the 2nd OS is connected to the switch outside the apartment (see diagram below). Product manual 2TMD041900D0015 │24...
  • Page 25 Commissioning Please follow the steps below: [1] On the "Outdoor station settings" screen, select "2nd OS" from the drop-down list. [2] Select "External" from the drop-down list. [3] Enter the block number (1…999). [4] Enter the room number (01…63 + 01…32 e.g. 0101). [5] Enter the device number (1…2).
  • Page 26: Unlock Type When Swiping Setting

    Commissioning 8.1.4 Unlock type when swiping setting This setting applies to pushbutton outdoor stations with card reader only. Please follow the steps below: [1] On the "Outdoor station settings" screen, select unlock type from the drop-down list. It can be set to "Default lock" or "Subsidiary lock". [2] Tap "...
  • Page 27: Default Lock Setting

    Commissioning 8.1.5 Default lock setting Please follow the steps below: [1] On the "Outdoor station settings" screen, select the lock type from the drop-down list. It can be set to "Lock-GND", "NO-NC-COM" or "IP Actuator". [2] If lock type = "IP actuator", you need to set the lock type from the drop-down list. It can be set to "Power lock"...
  • Page 28: Subsidiary Lock Setting

    Commissioning 8.1.6 Subsidiary lock setting Please follow the steps below: [1] On the "Outdoor station settings" screen, select lock type from the drop-down list. It can be set to "Lock-GND", "NO-NC-COM" or "IP Actuator". [2] If lock type = "IP actuator", you need to set the lock type from the drop-down list. It can be set to "Power lock"...
  • Page 29: Door Status Detection Setting

    Commissioning 8.1.7 Door status detection setting If this function is enabled, the IP touch will send an alarm to the management software when the door is open longer than 120 s (a sensor should first be connected to the outdoor station). Please follow the steps below: [1] On the "Outdoor station settings"...
  • Page 30: Tamper Proof Alarm Setting

    Commissioning 8.1.8 Tamper proof alarm setting If this function is enabled, the IP touch will send an alarm to the management software if the outdoor station is removed from the wall. Please follow the steps below: [1] On the "Outdoor station settings" screen, select the check box "Tamper proof alarm" to enable the function.
  • Page 31: Ringtone Volume Setting

    Commissioning 8.1.9 Ringtone volume setting Please follow the steps below: [1] On the "Outdoor station settings" screen, tap "+" or "-" to adjust the ringtone volume. [2] Tap " " to exit the setting, tap "OK" to save the settings. Product manual 2TMD041900D0015 │31...
  • Page 32: Button Tone Setting

    Commissioning 8.1.10 Button tone setting Please follow the steps below: [1] On the "Outdoor station settings" screen, tick the check box "Button tone" to enable the function. [2] Tap "+" or "-" to adjust the voice volume. [3] Tap " "...
  • Page 33: Voice Prompts Setting

    Commissioning 8.1.11 Voice prompts setting If this function is enabled, the outdoor station will play the sound for "Call in progress" during the operation. Please follow the steps below: [1] On the "Outdoor station settings" screen, tick the check box "Voice prompts" to enable the function.
  • Page 34: Language Setting

    Commissioning 8.1.12 Language setting Please follow the steps below: [1] On the "Outdoor station settings" screen, select a language from the drop-down list. [2] Tap " " to exit the setting, tap "OK" to save the settings. Product manual 2TMD041900D0015 │34...
  • Page 35: Lift Control Setting

    Commissioning 8.1.13 Lift control setting This setting is available when the device type of outdoor station is set to "OS". Please follow the steps below: [1] On the "Outdoor station settings" screen, tick the check box "Lift control settings" to enable the function.
  • Page 36: Anti-Flicker Setting

    Commissioning 8.1.14 Anti-flicker setting Please follow the steps below: [1] On the "Outdoor station settings" screen, select the refresh rate from the drop-down list. It can be set to "60 Hz" or "50 Hz". [2] Tap " " to exit the setting, tap "OK" to save the settings. Product manual 2TMD041900D0015 │36...
  • Page 37: Call Forward Setting

    Commissioning 8.1.15 Call forward setting This setting is available when the device type of outdoor station is set to "OS" or "GS". If this function is enabled, each incoming call from this outdoor station will be transferred to the designated guard unit. Please follow the steps below: [1] On the "Outdoor station settings"...
  • Page 38: Wiegand Setting

    Commissioning 8.1.16 Wiegand setting Please follow the steps below: [1] On the "Outdoor station settings" screen, select the check box "Wiegand output" to enable the function. [2] Select the Wiegand output format from the drop-down list. It can be set to "26 bits" or "34 bits".
  • Page 39: Push-Button Setting

    Commissioning 8.1.17 Push-button setting Please follow the steps below: [1] On the "Outdoor station settings" screen, select the columns of button from the drop-down list. This setting is only available when detecting the bar push-button module on the outdoor station. It can be set to "1" or "2" (optional). [2] Tap "Push-button address setting".
  • Page 40 Commissioning [3] Select the function from the drop-down list. It can be set to "Call", "Turn on the light" or "None". [4] Select the device type from the drop-down list. It can be set to "Indoor station" or "Phone guard unit". [5] Enter the address according to the device type.
  • Page 41: Time Sync Setting

    Commissioning 8.1.18 Time sync setting Please follow the steps below: [1] On the "Outdoor station settings" screen, select the sync time method from the drop-down list. It can be set to "Sync with mgmtc." or "Close time sync". If "Sync with mgmtc." is selected, the outdoor station will sync the time from the management software.
  • Page 42: Compatible Mode Setting

    Commissioning 8.1.19 Compatible mode setting The outdoor station works in security mode to guarantee high security ("Compatible mode" is disabled by default). It is suggested that compatible mode is only used when the devices need to communicate with previous generation products. In this mode, data transmission between devices is not encrypted, may lead to data leaks and has the risk of attacks.
  • Page 43: Updating The Firmware

    Commissioning 8.1.20 Updating the firmware Note The outdoor station must exit engineering mode before the firmware is upgraded. If the gate station (device type = GS) needs to update the firmware, a gate station (device ID =1) must be used before updating. If the building outdoor station (device type = OS) needs to update the firmware, a building outdoor station (device ID =1) must be used before updating.
  • Page 44 Commissioning [2] Select the designated outdoor station from the drop-down list. [3] Select the upgrade file from the SD card. [4] Tap "OK" to update the firmware. Product manual 2TMD041900D0015 │44...
  • Page 45: Viewing The Version

    Commissioning 8.1.21 Viewing the version On the "Outdoor station settings" screen, view the version information. Product manual 2TMD041900D0015 │45...
  • Page 46: Viewing The Serial Number

    Commissioning 8.1.22 Viewing the serial number On the "Outdoor station settings" screen, view the serial number. Product manual 2TMD041900D0015 │46...
  • Page 47: Configure The Settings On "Smart Access Point

    Commissioning Configure the settings on "Smart Access Point" 8.2.1 Adding mini outdoor station Note Only a mini outdoor station without a certificate can be added by SmartAP. This mini outdoor station will lose its certificate if its physical address is changed. The mini outdoor station needs to be powered on before being added.
  • Page 48: Configure The Settings

    Commissioning 8.2.2 Configure the settings On the configuration screen, click "Door entry system", "Outdoor stations", then click a mini outdoor station to access the settings. Product manual 2TMD041900D0015 │48...
  • Page 49 Commissioning Basic information Function Device ID Click the icon to return to the previous screen Overview of the outdoor station Device type of the outdoor station Display the address of the outdoor station Display the serial number of the outdoor station Display the firmware version of the outdoor station Product manual 2TMD041900D0015 │49...
  • Page 50 Commissioning Additional settings Function Set the physical address for the outdoor station. Unlock setting Enable or disable the time synchronization with the management software. Update the firmware via local PC. Update the firmware via the external website. Manage the trusted devices Product manual 2TMD041900D0015 │50...
  • Page 51 Commissioning Unlock setting Please follow the steps below: [1] On the designated outdoor station screen, click "Door lock setting". [2] Set the lock type for the locks, it can set to "Lock-GND", "NO-NC-COM" or "IP actuator". [3] Set the unlock time for the locks (1...10 seconds). [4] Click "√"...
  • Page 52 Commissioning If lock type is set to "IP actuator", please follow the steps below; [1] Click "Select IP actuator addr.". [2] Select the designated IP actuator. [3] Click "Confirm". Product manual 2TMD041900D0015 │52...
  • Page 53 Commissioning Manage the trusted device If you want to release the lock on the mini outdoor station, you need to check: The indoor station and the outdoor station have been signed on "Smart Access Point". ■ The indoor station has been added on the trusted list on the mini outdoor station. ■...
  • Page 54 Commissioning [3] Select the designated indoor stations to trusted list. [4] Click "√" to confirm. [5] [Optional] You need to enable the "Trust this management software" function if you want this outdoor station to unlock in the event of an emergency. [6] Click "Save".
  • Page 55: Card Management

    Commissioning Card management The chapter applies to the mini outdoor station integrated with ID card reader. Note It is recommended that ID cards are created and maintained using local outdoor station or management software only. 1. Card management on local outdoor station Programming Ring indicator Call indicator...
  • Page 56 Commissioning After entering the settings, following functionalities can be implemented: Function Action Unlock indicator Swipe admin card 1x Orange flashes 1x Enrol user Swipe user card 1x Green Swipe admin card 2x Orange flashes 2x Delete user Swipe user card 1x Green Swipe admin card 3x Orange flashes 3x...
  • Page 57: Restoring To Factory Default

    Commissioning Restoring to factory default Ring indicator Call indicator Unlock indicator 1st button Please follow the steps below: [1] Power on the device and wait a while 3 LED indicators will turn off. [2] Then press and hold the 1st button for 3 seconds within 30 seconds until 3 LED indicators begin to flash green at the same time to indicate the device entering configuration mode.
  • Page 58: Cyber Security

    Although ABB provides functionality testing on the products and updates that we release, you should institute your own testing program for any product updates or other major system updates (to include but not limited to code changes, configuration file changes, third party software updates or patches, hardware change out, etc.) to ensure that the security measures...
  • Page 59: Deployment Guideline

    Malware prevention solution The device is not susceptible to malware, because custom code cannot be executed on the system. The only way to update the software is via firmware upgrades. Only firmware signed by ABB can be accepted. Product manual 2TMD041900D0015 │59...
  • Page 60: Notice

    We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice. The detailed specifications agreed to at the time of ordering apply to all orders. ABB accepts no responsibility for possible errors or incompleteness in this document.