Tab le of c ont e nts Notes on the instruction manual ......................4 Safety ..............................4 Intended use ............................4 Environment ............................5 ABB devices ..........................5 Product description ..........................6 Device type ..........................6 Control elements........................7 Terminal description ........................8 Lock type and connection ......................
Page 3
Table of contents 8.1.21 Viewing the version....................... 45 8.1.22 Viewing the serial number ..................... 46 Configure the settings on "Smart Access Point" ................ 47 8.2.1 Adding mini outdoor station ....................47 8.2.2 Configure the settings ......................48 Card management ........................55 Restoring to factory default.......................
Please keep this manual in a safe place. If you pass the device on, also pass on this manual along with it. ABB accepts no liability for any failure to observe the instructions in this manual. Safety...
ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal. Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company.
Product description Product description Device type Size (HxWxD) Article Product ID Product name Colour number Unit: mm H81313P1-A 2TMA130010A0001 Mini video outdoor station, Aluminum 99 x 168 x 26 1 button, ID, SM alloy H81313P2-A 2TMA130010A0004 Mini video outdoor station, Aluminum 99 x 168 x 26 2 buttons, ID, SM...
Product description Terminal description EXIT AGND LOCK NC COM NO GND DC+ Description Connector for the sensor used for door status detection Connector for exit button Plug-in clamps (LOCK...AGND) for door opener Plug-in clamps (COM...NC...NO) for floating output Plug-in clamps (DC+...GND) for standalone power supply LAN (PoE) Product manual 2TMD041900D0015 │8...
Product description Lock type and connection Lock type Operation type Voltage Wiring type Electrical strike ⎓ Power on to open Type A/B 12 V lock, 12V Electrical strike ⎓ Power on to open Type B 24 V lock, 24V Electrical rim Power on to open ⎓...
Technical data Technical data Designation Value Rating voltage ⎓ 24 V Operating voltage range ⎓ 20-27 V ⎓ 27 V , 310 mA Rating current ⎓ 24 V , 350 mA Operating temperature -40 °C…+55 °C 99 mm x 168 mm × 26 mm (H8131.P.-.) Product dimensions 105 mm x 180 mm ×...
Mounting/Installation Mounting/Installation Warning Electric voltage! Dangerous currents flow through the body when coming into direct or indirect contact with live components. This can result in electric shock, burns or even death. – Disconnect the mains power supply prior to installation and/or disassembly! –...
Mounting/Installation 7.2.3 Installation situation Note The following installation situations must be avoided without fail to ensure picture quality: Direct light ■ Direct sunlight ■ Extremely bright picture background ■ Highly reflective walls on the opposite side of the door station ■...
Mounting/Installation 7.2.4 Surface-mounted installation Product dimension 99 mm 26.5 mm 78 mm 62 mm 60 mm Surface-mounted on the wall Mount ing screw x 4 ⌀ Screw shaf t: S cre w length: ≥ 25 mm Product manual 2TMD041900D0015 │14...
Page 15
Mounting/Installation Surface-mounted on the box (e.g. VDE box) Mounting screw x 4 ⌀ S crew shaft : S cre w le ngth: 25 mm ≥ Product manual 2TMD041900D0015 │15...
Mounting/Installation 7.2.5 Flush-mounted installation Product dimension 99 mm 45 mm 105 mm 53 mm 99 mm Flush-mounted with pre-installation box Mounting scre w x 4 ⌀ Screw sh aft : S cre w length: ≥ 25 mm Product manual 2TMD041900D0015 │16...
Mounting/Installation 7.2.6 Cavity wall installation Product dimension 92 mm 105 mm 43 mm 90 mm 97 mm Mounting Mounting screw x 4 ⌀ Screw shaft : Screw le ngth: ≥ 2 5 mm Product manual 2TMD041900D0015 │17...
Commissioning Commissioning Configure the settings on indoor station 8.1.1 Enter engineering mode of outdoor station Note The mini outdoor station must be on the same network as the indoor station. Unlock indicator Fi rst pushbutton P ushbutton m odule Please follow the steps below, Power up the mini outdoor station, the three indicators light up green.
Commissioning 8.1.2 Enter outdoor station through an indoor station On the extra screen of indoor station, click "System" to access the corresponding screen. On the "System settings" screen, click "Engineering settings", enter the engineering password to access the corresponding screen. Product manual 2TMD041900D0015 │20...
Page 21
Commissioning On the "Engineering settings" screen, tap "Outdoor station settings" to access the corresponding screen. Product manual 2TMD041900D0015 │21...
Commissioning 8.1.3 Device type settings 1. Device type = OS (outdoor station) Please follow the steps below: [1] On the "Outdoor station settings" screen, select "OS" from the drop-down list. [2] Enter the block number (1…999). [3] Enter the device number (1…64). [4] Tap "...
Page 23
Commissioning 2. Device type = 2nd OS (2nd confirmed outdoor station) Location of IP gateway = Internal In this case, the 2nd OS is connected to the router in the apartment (see diagram below). Please follow the steps below: [1] On the "Outdoor station settings" screen, select "2nd OS" from the drop-down list. [2] Select "Internal"...
Page 24
Commissioning Location of IP gateway = External In this case, the 2nd OS is connected to the switch outside the apartment (see diagram below). Product manual 2TMD041900D0015 │24...
Page 25
Commissioning Please follow the steps below: [1] On the "Outdoor station settings" screen, select "2nd OS" from the drop-down list. [2] Select "External" from the drop-down list. [3] Enter the block number (1…999). [4] Enter the room number (01…63 + 01…32 e.g. 0101). [5] Enter the device number (1…2).
Commissioning 8.1.4 Unlock type when swiping setting This setting applies to pushbutton outdoor stations with card reader only. Please follow the steps below: [1] On the "Outdoor station settings" screen, select unlock type from the drop-down list. It can be set to "Default lock" or "Subsidiary lock". [2] Tap "...
Commissioning 8.1.5 Default lock setting Please follow the steps below: [1] On the "Outdoor station settings" screen, select the lock type from the drop-down list. It can be set to "Lock-GND", "NO-NC-COM" or "IP Actuator". [2] If lock type = "IP actuator", you need to set the lock type from the drop-down list. It can be set to "Power lock"...
Commissioning 8.1.6 Subsidiary lock setting Please follow the steps below: [1] On the "Outdoor station settings" screen, select lock type from the drop-down list. It can be set to "Lock-GND", "NO-NC-COM" or "IP Actuator". [2] If lock type = "IP actuator", you need to set the lock type from the drop-down list. It can be set to "Power lock"...
Commissioning 8.1.7 Door status detection setting If this function is enabled, the IP touch will send an alarm to the management software when the door is open longer than 120 s (a sensor should first be connected to the outdoor station). Please follow the steps below: [1] On the "Outdoor station settings"...
Commissioning 8.1.8 Tamper proof alarm setting If this function is enabled, the IP touch will send an alarm to the management software if the outdoor station is removed from the wall. Please follow the steps below: [1] On the "Outdoor station settings" screen, select the check box "Tamper proof alarm" to enable the function.
Commissioning 8.1.9 Ringtone volume setting Please follow the steps below: [1] On the "Outdoor station settings" screen, tap "+" or "-" to adjust the ringtone volume. [2] Tap " " to exit the setting, tap "OK" to save the settings. Product manual 2TMD041900D0015 │31...
Commissioning 8.1.10 Button tone setting Please follow the steps below: [1] On the "Outdoor station settings" screen, tick the check box "Button tone" to enable the function. [2] Tap "+" or "-" to adjust the voice volume. [3] Tap " "...
Commissioning 8.1.11 Voice prompts setting If this function is enabled, the outdoor station will play the sound for "Call in progress" during the operation. Please follow the steps below: [1] On the "Outdoor station settings" screen, tick the check box "Voice prompts" to enable the function.
Commissioning 8.1.12 Language setting Please follow the steps below: [1] On the "Outdoor station settings" screen, select a language from the drop-down list. [2] Tap " " to exit the setting, tap "OK" to save the settings. Product manual 2TMD041900D0015 │34...
Commissioning 8.1.13 Lift control setting This setting is available when the device type of outdoor station is set to "OS". Please follow the steps below: [1] On the "Outdoor station settings" screen, tick the check box "Lift control settings" to enable the function.
Commissioning 8.1.14 Anti-flicker setting Please follow the steps below: [1] On the "Outdoor station settings" screen, select the refresh rate from the drop-down list. It can be set to "60 Hz" or "50 Hz". [2] Tap " " to exit the setting, tap "OK" to save the settings. Product manual 2TMD041900D0015 │36...
Commissioning 8.1.15 Call forward setting This setting is available when the device type of outdoor station is set to "OS" or "GS". If this function is enabled, each incoming call from this outdoor station will be transferred to the designated guard unit. Please follow the steps below: [1] On the "Outdoor station settings"...
Commissioning 8.1.16 Wiegand setting Please follow the steps below: [1] On the "Outdoor station settings" screen, select the check box "Wiegand output" to enable the function. [2] Select the Wiegand output format from the drop-down list. It can be set to "26 bits" or "34 bits".
Commissioning 8.1.17 Push-button setting Please follow the steps below: [1] On the "Outdoor station settings" screen, select the columns of button from the drop-down list. This setting is only available when detecting the bar push-button module on the outdoor station. It can be set to "1" or "2" (optional). [2] Tap "Push-button address setting".
Page 40
Commissioning [3] Select the function from the drop-down list. It can be set to "Call", "Turn on the light" or "None". [4] Select the device type from the drop-down list. It can be set to "Indoor station" or "Phone guard unit". [5] Enter the address according to the device type.
Commissioning 8.1.18 Time sync setting Please follow the steps below: [1] On the "Outdoor station settings" screen, select the sync time method from the drop-down list. It can be set to "Sync with mgmtc." or "Close time sync". If "Sync with mgmtc." is selected, the outdoor station will sync the time from the management software.
Commissioning 8.1.19 Compatible mode setting The outdoor station works in security mode to guarantee high security ("Compatible mode" is disabled by default). It is suggested that compatible mode is only used when the devices need to communicate with previous generation products. In this mode, data transmission between devices is not encrypted, may lead to data leaks and has the risk of attacks.
Commissioning 8.1.20 Updating the firmware Note The outdoor station must exit engineering mode before the firmware is upgraded. If the gate station (device type = GS) needs to update the firmware, a gate station (device ID =1) must be used before updating. If the building outdoor station (device type = OS) needs to update the firmware, a building outdoor station (device ID =1) must be used before updating.
Page 44
Commissioning [2] Select the designated outdoor station from the drop-down list. [3] Select the upgrade file from the SD card. [4] Tap "OK" to update the firmware. Product manual 2TMD041900D0015 │44...
Commissioning Configure the settings on "Smart Access Point" 8.2.1 Adding mini outdoor station Note Only a mini outdoor station without a certificate can be added by SmartAP. This mini outdoor station will lose its certificate if its physical address is changed. The mini outdoor station needs to be powered on before being added.
Commissioning 8.2.2 Configure the settings On the configuration screen, click "Door entry system", "Outdoor stations", then click a mini outdoor station to access the settings. Product manual 2TMD041900D0015 │48...
Page 49
Commissioning Basic information Function Device ID Click the icon to return to the previous screen Overview of the outdoor station Device type of the outdoor station Display the address of the outdoor station Display the serial number of the outdoor station Display the firmware version of the outdoor station Product manual 2TMD041900D0015 │49...
Page 50
Commissioning Additional settings Function Set the physical address for the outdoor station. Unlock setting Enable or disable the time synchronization with the management software. Update the firmware via local PC. Update the firmware via the external website. Manage the trusted devices Product manual 2TMD041900D0015 │50...
Page 51
Commissioning Unlock setting Please follow the steps below: [1] On the designated outdoor station screen, click "Door lock setting". [2] Set the lock type for the locks, it can set to "Lock-GND", "NO-NC-COM" or "IP actuator". [3] Set the unlock time for the locks (1...10 seconds). [4] Click "√"...
Page 52
Commissioning If lock type is set to "IP actuator", please follow the steps below; [1] Click "Select IP actuator addr.". [2] Select the designated IP actuator. [3] Click "Confirm". Product manual 2TMD041900D0015 │52...
Page 53
Commissioning Manage the trusted device If you want to release the lock on the mini outdoor station, you need to check: The indoor station and the outdoor station have been signed on "Smart Access Point". ■ The indoor station has been added on the trusted list on the mini outdoor station. ■...
Page 54
Commissioning [3] Select the designated indoor stations to trusted list. [4] Click "√" to confirm. [5] [Optional] You need to enable the "Trust this management software" function if you want this outdoor station to unlock in the event of an emergency. [6] Click "Save".
Commissioning Card management The chapter applies to the mini outdoor station integrated with ID card reader. Note It is recommended that ID cards are created and maintained using local outdoor station or management software only. 1. Card management on local outdoor station Programming Ring indicator Call indicator...
Page 56
Commissioning After entering the settings, following functionalities can be implemented: Function Action Unlock indicator Swipe admin card 1x Orange flashes 1x Enrol user Swipe user card 1x Green Swipe admin card 2x Orange flashes 2x Delete user Swipe user card 1x Green Swipe admin card 3x Orange flashes 3x...
Commissioning Restoring to factory default Ring indicator Call indicator Unlock indicator 1st button Please follow the steps below: [1] Power on the device and wait a while 3 LED indicators will turn off. [2] Then press and hold the 1st button for 3 seconds within 30 seconds until 3 LED indicators begin to flash green at the same time to indicate the device entering configuration mode.
Although ABB provides functionality testing on the products and updates that we release, you should institute your own testing program for any product updates or other major system updates (to include but not limited to code changes, configuration file changes, third party software updates or patches, hardware change out, etc.) to ensure that the security measures...
Malware prevention solution The device is not susceptible to malware, because custom code cannot be executed on the system. The only way to update the software is via firmware upgrades. Only firmware signed by ABB can be accepted. Product manual 2TMD041900D0015 │59...
We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice. The detailed specifications agreed to at the time of ordering apply to all orders. ABB accepts no responsibility for possible errors or incompleteness in this document.
Page 61
Contact us Notice We reserve the right to at all times make technical changes as well as ABB Xiamen Smart Technology Co., Ltd. changes to the contents of this No. 881, FangShanXiEr Road, Xiang’An Industrial document without prior notice. Area, Torch Hi-Tech Industrial Development...