Tab le of c ont e nts Notes on the instruction manual ......................4 Safety ..............................4 Intended use ............................4 Environment ............................5 ABB devices ..........................5 Product description ..........................6 Device type ..........................6 Control elements........................7 Terminal description ........................8 Lock type and connection ......................
– Permit work on the 100-240 V supply system to be performed only by specialist staff! Intended use As part of the ABB i-HD system, this device can only be used with accessories from that system. │4 Product manual 2TMD042100D0003...
ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal. Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company.
Product description Product description Device type Size (HxWxD) Article Product ID Product name Colour number Unit: mm H81365P1-A 2TMA130011A0001 Mini video outdoor station, Aluminum 105 x 180 x 43 1 button, IC, FM alloy H81365P2-A 2TMA130011A0002 Mini video outdoor station, Aluminum 105 x 180 x 43 2 buttons, IC, FM...
Product description Terminal description EXIT AGND LOCK NC COM NO GND DC+ Description Connector for the sensor used for door status detection Connector for exit button Plug-in clamps (LOCK...AGND) for door opener Plug-in clamps (COM...NC...NO) for floating output Plug-in clamps (DC+...GND) for standalone power supply LAN (PoE) │8 Product manual 2TMD042100D0003...
Product description Lock type and connection Lock type Operation type Voltage Wiring type Electrical strike ⎓ Power on to open Type A/B 12 V lock, 12V Electrical strike ⎓ Power on to open Type B 24 V lock, 24V Electrical rim ⎓...
Technical data Technical data Designation Value ⎓ Rating voltage 24 V ⎓ Operating voltage range 20-27 V ⎓ 27 V , 310 mA Rating current ⎓ 24 V , 350 mA Operating temperature -40 °C…+55 °C Product dimensions 105 x 180 × 43 mm Camera type CMOS Camera viewing angle...
Mounting/Installation Mounting/Installation Warning Electric voltage! Dangerous currents flow through the body when coming into direct or indirect contact with live components. This can result in electric shock, burns or even death. – Disconnect the mains power supply prior to installation and/or disassembly! –...
Mounting/Installation 7.2.3 Installation situation Note The following installation situations must be avoided without fail to ensure picture quality: ■ Direct light ■ Direct sunlight ■ Extremely bright picture background ■ Highly reflective walls on the opposite side of the door station │13 Product manual 2TMD042100D0003...
Mounting/Installation 7.2.4 Flush-mounted installation Product dimension 99 mm 45 mm 105 mm 53 mm 99 mm Flush-mounted with pre-installation box Mounting scre w x 4 ⌀ Screw sh aft : S cre w length: ≥ 25 mm │14 Product manual 2TMD042100D0003...
Mounting/Installation 7.2.5 Cavity wall installation Product dimension 92 mm 105 mm 43 mm 90 mm 97 mm Mounting Mounting screw x 4 ⌀ Screw shaft : Screw le ngth: ≥ 2 5 mm │15 Product manual 2TMD042100D0003...
Commissioning Commissioning Configure the settings on indoor station 8.1.1 Outdoor station enters engineering mode Note The mini outdoor station must be in the same network with the indoor station. Please follow the steps below, Power up the mini outdoor station, three indicators light green. ■...
Commissioning 8.1.2 Indoor station enters engineering settings On the extra screen of indoor station, click "System" to access the corresponding screen. On the "System settings" screen, click "Engineering settings", enter the engineering password and then click "Outdoor station settings" to access the corresponding screen. │17 Product manual 2TMD042100D0003...
Commissioning 8.1.3 Local device settings On the "Outdoor station settings" screen, select the device type = "2nd OS". [1] Location = Internal With this setting, 2nd OS is connected to the router in the apartment. │18 Product manual 2TMD042100D0003...
Page 19
Commissioning [2] Location = External With this setting, 2nd OS is connected to the switch outside the apartment. Note The external and internal types cannot be used in mixed scenarios in the same apartment. │19 Product manual 2TMD042100D0003...
Commissioning 8.1.4 Lock management On the "Outdoor station settings" screen, Function Unlock type when swiping Set the lock to be released when swiping. ■ Default lock (default) ■ Subsidiary lock. Lock type Set the lock type for the default lock and subsidiary lock. ■...
Commissioning 8.1.5 Door status detection Go to the "Outdoor station settings" screen. Function Door status detection If this function is enable, the outdoor station will send an alarm to the management software if the door is open longer than 120 s (A sensor should first be connected to the outdoor station). Tamper proof alarm If this function is enabled, the outdoor station will send an alarm to the management software if the outdoor station is removed from the wall.
Commissioning 8.1.6 Sound setting Got to the "Outdoor station settings" screen. Function Volume of outdoor station Click "+" or "-" to adjust the ringtone volume and the voice volume on the outdoor station. Button tone Tick the checkbox to enable button tones on the outdoor station. Voice prompt ■...
Commissioning 8.1.7 Anti-flicker setting On the "Outdoor station settings" screen, select the refresh rate from the drop-down list. │23 Product manual 2TMD042100D0003...
Commissioning 8.1.8 Card mode On the "Outdoor station settings" screen, tick/untick the checkbox to enable/disable the function. When the "Safe mode" is enabled, ID card will not be supported by this outdoor station. │24 Product manual 2TMD042100D0003...
Commissioning 8.1.9 Set the function of pushbutton On the "Outdoor station settings" screen, click "Pushbutton address setting" to access the settings of the pushbuttons. Note Device no. should be entered if "Phone guard unit" is selected. │25 Product manual 2TMD042100D0003...
Commissioning 8.1.10 Time sync setting On the "Outdoor station settings" screen. If "Sync time with management" is selected, the outdoor station will sync the time from the management software. If "Close time sync" is selected, the time and date needs to be set manually. │26 Product manual 2TMD042100D0003...
Commissioning 8.1.11 Compatible mode setting On the "Outdoor station settings" screen, the outdoor station is set to "Security mode" by default (Compatible mode = off). │27 Product manual 2TMD042100D0003...
Commissioning 8.1.12 Updating the firmware Note The outdoor station doesn’t need to enter engineering mode when you want to upgrade the firmware. On the "Outdoor station settings" screen, click "Firmware update", select the outdoor station and the file from SD card, then click "OK" to update the firmware. │28 Product manual 2TMD042100D0003...
Commissioning 8.1.14 Serial number On the "Outdoor station settings" screen, view the serial number, this number is used to get the signature from the management software. │30 Product manual 2TMD042100D0003...
Commissioning Configure the settings on PC management software Please see the product manual of "ABB i-HD management software" for more details. │32 Product manual 2TMD042100D0003...
Commissioning Card management Note It is recommended that IC cards are created and maintained using local outdoor station or management software only. 1. Card management on local outdoor station Programming The system will take the first card swiped after powering up the system within 60s as the admin card.
Page 34
Mifare one S50/S70, Mifare desfire EV1/EV2 Note A maximum of 64 IC cards can be supported by mini outdoor station. 2. Card management on management software Please see the "ABB i-HD management software" product manual for more details. │34 Product manual 2TMD042100D0003...
Although ABB provides functionality testing on the products and updates that we release, you should institute your own testing program for any product updates or other major system updates (to include but not limited to code changes, configuration file changes, third party software updates or patches, hardware change out, etc.) to ensure that the security measures...
Page 36
Malware prevention solution The device is not susceptible to malware, because custom code cannot be executed on the system. The only way to update the software is via firmware upgrades. Only firmware signed by ABB can be accepted. │36 Product manual 2TMD042100D0003...
Page 37
We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice. The detailed specifications agreed to at the time of ordering apply to all orders. ABB accepts no responsibility for possible errors or incompleteness in this document.
Page 38
Contact us Notice We reserve the right to at all times make technical changes as well as ABB Xiamen Smart Technology Co., Ltd. changes to the contents of this No. 881, FangShanXiEr Road, Xiang’An Industrial document without prior notice. Area, Torch Hi-Tech Industrial Development...