Specifications - GE VAT20 Instruction Manual

Ac speed control equipment
Hide thumbs Also See for VAT20:
Table of Contents

Advertisement

3

Specifications

 
Model No: VAT20-
Suitable Motor Power Rating (KW)
Motor HP
Rated
Current A
Capacity KVA
Weight (Kg )
Input Voltage Max.
Output Voltage Max.
Input Signal Type
Control Method
Freq. Range
Resolution Setting
Freq.
Control
Keyboard Setting
External Signal Setting
Other function
Accelerate/Decelerate time
V/F Pattern
Torque control
General
Multi-Function input
Control
Multi-Function output
Braking Torque
Other function
Indication function
Operating temperature
Humidity
Vibration
EMC specification
Protection level
UL
Overload protection
Over-voltage
Protection
Under voltage
function
Momentary power-loss
Stall Prevention
Output terminal short-circuit
Protection
Grounding fault
function
Other function
Dimension(W*H*D) mm
Installation
U20N0K2S U20N0K4S U20N0K7S U20N1K5S U20N2K2S
0.2
0.4
1/4
1/2
1.4
2.3
0.53
0.88
0.76
0.77
Single phase 200-240V (+10%-15%) , 50/60Hz (+/-5%)
Three phase 200-240V +10%-15% (Input Voltage Max)
PNP type (SOURCE) input
Sinusoidal wave PWM control
0~120 Hz
Digital : 0.1 Hz(0~99.9Hz); 1Hz(100~120Hz)
Analog:0.06Hz/60Hz

Directly setup by
buttons.
0~10V, 4~20mA , 0~20mA
Frequency upper and lower limit
0.1~ 999 Sec
6 Patterns
Torque boost level adjustable (manual torque boost)
2 point, to be used as multi-speed 1(Sp1) / Jog / External
emergency stop / External bb / Reset
1a Relay terminal, to be setup as Fault / Running / Frequency.
About 20%, additional breaking resistance not allowed
Decelerate or free run stop, Auto reset, DC braking frequency
/ Voltage / Time can be setup by constants.
7 segments*3 indicate frequency / inverter parameter / fault
record / program version.
O
-10 ~ 40
C
0~95% RH non-condensing.
2
Under 1 G ( 9.8 m/s
)
Class A ( Filter build in )
IP20
UL508C
150% for 1min.
DC voltage > 410V
DC voltage < 200V
0 ~ 2 sec : VAT20 can be restart by speed search
Accelerate / Decelerate / Constant speed
Electronic circuitry protection
Electronic Circuitry protection
Heat sink protection , Current limit
72*132*118
Install by mounting screw or DIN rail (Option).
7
0.75
1.5
1
2
4.2
7.5
1.6
2.9
0.8
1.5
115*140*145
2.2
3
10.5
4.0
1.6

Advertisement

Table of Contents
loading

Table of Contents