There are 4 different types of messages:
Information messages help and give hints on how to
operate the product. An information message is
shown as an information symbol in the bottom bar.
Caution messages show that something is not
correct. A caution message is shown as a yellow
triangle in the bottom bar.
Warning messages show faults or safety defects that
can cause mechanical damage. The product will
stop in a short time. The warning is first shown in full
screen with a red warning triangle and text. After you
accepted (C) the warning message, the warning is
shown as a red triangle symbol in the bottom bar (A).
REPLACE WITH CHARGED BATTERY SOON
F
Fault code number
1
2
3
5
6
7
10
1401 - 002 - 15.10.2021
C
BATTERY
LOW
Message in the dis-
play
"Softstart error Start
not possible"
"Softstart error Over-
load"
"Wrong incoming
voltage Phase lost"
"Wrong incoming
voltage Grid frequen-
cy"
"Wrong incoming
voltage Voltage too
low"
"Wrong incoming
voltage Voltage too
high"
"Grid frequency Out
of range"
Error messages show when the product is stopped
because of a fault or safety defect. The error
message is shown in red with a white triangle and
white text. When the fault is corrected you must
restart the product, turn the OFF/ON/START switch
to ON position. Then turn the OFF/ON/START
switch to START position.
If there are more than 1 active message, the newest
message is added from the right. Push the buttons
adjacent to the arrows (D and E) to move between the
messages in the display.
You can also find a fault list in the "Active faults" in
"Machine status" in the menu button (F). Refer to
"Machine status" menu on page 37 .
D
Fault codes and descriptions
The fault code numbers for the product are shown on
the display. The fault code numbers for the remote
control (fault code numbers from 1001) are shown on
the information center display.
E
Cause
General error in soft starter.
Softstart is overload. The input
voltage is out of range.
Incorrect input voltage and phase
loss.
The grid frequency is out of
range.
The input voltage is too low.
The input voltage is too high.
The grid frequency does not
agree with the product frequency
setting.
Solution
Speak to Husqvarna service.
Do a check of the input voltage.
Let the product become cool. If
the problem stays, speak to
Husqvarna service.
Do a check of the input voltage
and the cables.
Do a check of the voltage source.
Do a check of the input voltage
and the cables.
Speak to Husqvarna service.