To replace a fuse (DXR 145)
WARNING:
serious injury and death. Read the safety
instructions in this manual carefully and
make sure that you understand the
instructions before you do servicing on the
product.
1. Stop the product and disconnect the power cord.
To stop the product (DXR 145) on page 62 .
Refer to
2. Open the cover of the electrical enclosure.
3. Replace blown fuses. Refer to the decal (C) and
Fuse overview on page 90 .
A
B
Note:
(A) is Fuse F2-F8, (B) is Fuse F1.
4. Close the cover of the electrical enclosure.
To replace a fuse (DXR 275, DXR 305,
DXR 315)
WARNING:
serious injury and death. Read the safety
instructions in this manual carefully and
make sure you understand the instructions
you do servicing on the product.
1. Stop the product and disconnect the power cord.
To stop the product (DXR 275, DXR 305,
Refer to
DXR 315) on page 62 .
2. Open the cover of the electrical enclosure.
90
Electricity can cause
C
Electricity can cause
3. Replace blown fuses. Refer do the decal (C) and
Fuse overview on page 90 .
C
Note:
(A) is Fuse F2-F8, (B) is Fuse F1.
4. Close the cover of the electrical enclosure.
Fuse overview
Fuse
Cur-
Volt-
rent
age
F1
4 A
400
VAC
F2
15 A
24
VDC
F3
10 A
24
VDC
F4
10 A
24
VDC
F5
10 A
24
VDC
F6
10 A
24
VDC
F7
1 A
24
VDC
F8
3 A
24
VDC
Product software
Speak to your service agent if there is a problem with
the product software or for updates that can be
necessary.
B
A
Description of protected
components
T1:AC/DC, KE4: Power mo-
tor
M2: Cooling Fan
M3: Oil filling pump
KE1: PLC, Master
KE2: PLC, 1/0 Slave 1
KE3: PLC, 1/0 Slave 2
KE4: Power meter
KE5: Radio receiver