Remote control
Battery specification
Battery
Operation time, h
Charge time, h
Signal transmission
Radio frequency bands
Max. radio frequency power transmitted, dBm
Range, m
Dimensions, mm/in.
Weight, kg/lb
Protection class
Operating temperature
Storage temperature with battery, °C/°F
Storage temperature without battery, °C/°F
Charging temperature, °C/°F
Operating temperatures for the cooling
kit (DXR 275, DXR 305, DXR 315)
At increased ambient temperature it is necessary to cool
down the air at the hydraulic system and the motor. The
Ambient temperature less then
Standard
It is not necessary to cool down
Kit 1
It is not necessary to cool down
Kit 2
It is not necessary to cool down
4
108
40°C / 104ºF
the air.
the air.
the air.
13dBm for markets that do not accept 20dBm.
DXR 145
DXR 275
Nominal 7.2V, 5100 mAh
2 x Li-ion batteries supplied with the product.
Radio signal transmission or cable.
400x216x291/15.7x8.5x11.5
Less than 1 month: -20–50°C / 4–122°F
Less than 3 month: -20–40°C / 4–104°F
Less than 1 year: -20–20°C / 4–68°F
maximum temperature for the compressed air is 30°C/
86°F and the maximum pressure is 10 bar/145 PSI.
Ambient temperature between
40-50°C / 104-122°F
N/A
N/A
Pressure,
6/87
bar/PSI
Flow, l/min or
1350/47.7
cu ft/min
DXR 305
12
3
2.4 GHz
4
20
Up to 300
3.25/7.2
IP65
-20–60°C /-4–140°F
-40–80°C / -40–176°F
10–45°C /50–113°F
Ambient temperature between
50-55°C / 122-131°F
Pressure,
bar/PSI
Flow, l/min or
cu ft/min
1401 - 002 - 15.10.2021
DXR 315
N/A
N/A
10/145
1650/58.3

Advertisement