Appendix 2
(Standard to comply with: UL 508C, CSA C22.2 No.14)
 General precaution
CAUTION - Risk of Electric Shock -
The bus capacitor discharge time is 10 minutes. Before starting wiring or inspection, switch power off, wait for more than 10 minutes, and check for residual
voltage between terminal P/+ and N/- with a meter etc., to avoid a hazard of electrical shock.
ATTENTION - Risque de choc électrique -
La durée de décharge du condensateur de bus est de 10 minutes. Avant de commencer le câblage ou l'inspection, mettez l'appareil hors tension et attendez plus
de 10 minutes.
 Installation
The below types of inverter have been approved as products for use in enclosure and approval tests were conducted under the following conditions.
Design the enclosure so that the surrounding air temperature, humidity and ambience of the inverter will satisfy the specifications. (Refer to
 Wiring protection
For installation in the United States, Class T, Class J, Class CC, or Class L fuse, UL 489 Molded Case Circuit Breaker (MCCB), or Type E combination motor
controller must be provided, in accordance with the National Electrical Code and any applicable local codes.
For installation in Canada, Class T, Class J, Class CC, or Class L fuse, UL 489 Molded Case Circuit Breaker (MCCB), or Type E combination motor controller
must be provided, in accordance with the Canadian Electrical Code and any applicable local codes.
For the FR-F820 series, Class T, Class J, or Class CC fuse, UL 489 Molded Case Circuit Breaker (MCCB), or Type E combination motor controller must be
provided.
FR-F820-[]
Rated fuse voltage (V)
Without power factor improving reactor
Fuse Maximum
allowable rating (A)

With power factor improving reactor
Molded case circuit breaker (MCCB)
Maximum allowable rating (A)

Maximum current rating (A)
Type E combination
motor controller

Maximum SCCR (kA)
FR-F820-[]
Rated fuse voltage (V)
Without power factor improving reactor
Fuse Maximum
allowable rating (A)

With power factor improving reactor
Molded case circuit breaker (MCCB)
Maximum allowable rating (A)

Maximum current rating (A)
Type E combination
motor controller
Maximum SCCR (kA)
FR-F840-[]
Rated fuse voltage (V)
Without power factor improving reactor
Fuse Maximum
allowable rating (A)

With power factor improving reactor
Molded case circuit breaker (MCCB)
Maximum allowable rating (A)

Maximum current rating (A)
Type E combination
motor controller

Maximum SCCR (kA)
FR-F840-[]
Rated fuse voltage (V)
Without power factor improving reactor
Fuse Maximum
allowable rating (A)

With power factor improving reactor
Molded case circuit breaker (MCCB)
Maximum allowable rating (A)

Maximum current rating (A)
Type E combination
motor controller
Maximum SCCR (kA)

Maximum allowable rating by the US National Electrical Code. Exact size must be chosen for each installation.

For UL/cUL certification, use the following product.
Model
MMP-T32

Suitable for Use in a Circuit Capable of Delivering Not More Than 50 or 25 kA rms Symmetrical Amperes, 480Y/277 Volts Maximum when protected by the Type E
Combination motor Controllers indicated in the above table.
 Wiring to the power supply and the motor
For wiring the input (R/L1, S/L2, T/L3) and output (U, V, W) terminals of the inverter, use the UL listed copper, stranded wires (rated at 75
terminals. Crimp the terminals with the crimping tool recommended by the terminal manufacturer.
 Short circuit ratings
• 200 V class
Suitable For Use in A Circuit Capable of Delivering Not More Than 100 kA rms Symmetrical Amperes, 240 V Maximum.
• 400 V class
Suitable For Use in A Circuit Capable of Delivering Not More Than 100 kA rms Symmetrical Amperes, 500 V Maximum.
30
Appendix
Instructions for UL and cUL
00046
00077
(0.75K)
(1.5K)
240 V or more
15
20
15
20
15
15
8
13
50
50

00930
01250
(22K)
(30K)
240 V or more
225
300
200
250
225
300
00023
00038
(0.75K)
(1.5K)
500 V or more
6
10
6
10
15
15
4
6.3
50
50

00930
01160
(45K)
(55K)
500 V or more
200
250
175
200
225
250
Manufacturer
Mitsubishi Electric Corp.
00105
00167
00250
00340
(2.2K)
(3.7K)
(5.5K)
(7.5K)
30
40
60
80
20
30
50
70
25
40
60
80
18
25
32
50
25
25
01540
01870
02330
03160
(37K)
(45K)
(55K)
(75K)
350
400
500
300
350
400
500
350
450
500
700
00052
00083
00126
00170
(2.2K)
(3.7K)
(5.5K)
(7.5K)
15
20
30
40
10
15
25
35
15
20
30
40
8
13
18
25
50
50
50
25
01800
02160
02600
03250
(75K)
(90K)
(110K)
(132K)
250
300
350
400
450
450
500
Rated voltage, VAC
480Y/277
page
00490
00630
00770
(11K)
(15K)
(18.5K)
150
175
200
125
150
200
110
150
190
03800
04750
(90K)
(110K)
600
700
900
1000
00250
00310
00380
00470
(11K)
(15K)
(18.5K)
(22K)
70
80
90
110
60
70
90
100
60
70
90
100
32
25
03610
04320
04810
05470
(160K)
(185K)
(220K)
(250K)
500
600
700
800
) and round crimping
°C
3.)
00620
00770
(30K)
(37K)
150
175
125
150
150
175
06100
06830
(280K)
(315K)
900
1000

Advertisement

loading