7

SPECIFICATIONS

7.1
Rating
200 V class
Model FR-F820-[ ]
SLD
0.75
Applicable motor
capacity (kW)

LD
0.75
SLD
1.8
Rated capacity
(kVA)

LD
1.6
SLD
4.6
Rated current
(A)
LD
4.2
SLD
110% 60 s, 120% 3 s (inverse-time characteristics) at surrounding air temperature of 40°C
Overload
current rating

LD
120% 60 s, 150% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
Rated voltage
Three-phase 200 to 240 V

Rated input
Three-phase 200 to 240 V 50 Hz/60 Hz
AC voltage/frequency
Permissible AC voltage fluctuation
170 to 264 V 50 Hz/60 Hz
Permissible frequency fluctuation
±5%
SLD
5.3
Without DC
reactor
LD
5
Rated input
current (A)

SLD
4.6
With DC
reactor
LD
4.2
SLD
2
Without DC
Power supply
reactor
LD
1.9
capacity (kVA)
SLD
1.8
With DC

reactor
LD
1.6
Protective structure (IEC 60529)
Enclose type (IP20)

Cooling system
Self-cooling
Approx. mass (kg)
1.9

The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.

The rated output capacity indicated assumes that the output voltage is 220 V for 200 V class.

The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time for the inverter
and motor to return to or below the temperatures under 100% load.

The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However, the maximum
point of the voltage waveform at the inverter output side is the power supply voltage multiplied by about

The rated input current indicates a value at a rated output voltage. The impedance at the power supply side (including those of the input reactor and cables) affects the
rated input current.

The power supply capacity is the value when at the rated output current. It varies by the impedance at the power supply side (including those of the input reactor and
cables).

FR-DU08: IP40 (except for the PU connector section)
00046 00077 00105 00167 00250 00340 00490 00630 00770 00930 01250 01540 01870 02330 03160 03800 04750
0.75K
1.5K
2.2K
3.7K
5.5K
1.5
2.2
3.7
5.5
7.5
1.5
2.2
3.7
5.5
7.5
2.9
4
6.4
10
13
2.7
3.7
5.8
8.8
12
7.7
10.5
16.7
25
34
7
9.6
15.2
23
31
8.9
13.2
19.7
31.3
45.1
8.3
12.2
18.3
28.5
41.6
7.7
10.5
16.7
25
34
7
9.6
15.2
23
31
3.4
5
7.5
12
17
3.2
4.7
7
11
16
2.9
4
6.4
10
13
2.7
3.7
5.8
8.8
12
Forced air cooling
2.1
3.0
3.0
3.0
6.3
7.5K
11K
15K
18.5K
22K
11
15
18.5
22
30
11
15
18.5
22
30
19
24
29
35
48
17
22
27
32
43
49
63
77
93
125
45
58
70.5
85
114
62.8
80.6
96.7
115
151
58.2
74.8
90.9
106
139
49
63
77
93
125
45
58
71
85
114
24
31
37
44
58
22
29
35
41
53
19
24
29
35
48
17
22
27
32
43
Open type (IP00)
6.3
8.3
15
15
15
.
30K
37K
45K
55K
75K
37
45
55
75
90/110 132
37
45
55
75
90
59
71
89
120
145
53
65
81
110
132
154
187
233
316
380
140
170
212
288
346
185
221
269
178
207
255
154
187
233
316
380
140
170
212
288
346
70
84
103
68
79
97
59
71
89
120
145
53
65
81
110
132
22
42
42
54
74
SPECIFICATIONS
Rating
90K
110K
110
181
165
475
432
475
432
181
165
74
25