Setting
Pr.
Name
range
Acceleration/
0 to 590Hz,
147
deceleration time
9999
switching frequency
Stall prevention level at
148
0 to 400%
0 V input
Stall prevention level at
149
0 to 400%
10 V input
Output current
150
0 to 400%
detection level
Output current detection
151
0 to 10s
signal delay time
Zero current detection
152
0 to 400%
level
Zero current detection
153
0 to 10s
time
Voltage reduction
154
selection during stall
0, 1, 10, 11
prevention operation
RT signal function
155
validity condition
0, 10
selection
Stall prevention
0 to 31, 100,
156
operation selection
101
157
OL signal output timer
0 to 25s, 9999 0s
1 to 3, 5 to 14,
17, 18, 21, 24,
AM terminal function
158
34, 50, 52 to 54,
selection
61, 62, 67, 69,
70, 86 to 96, 98
Automatic switchover
frequency range from
0 to 10Hz,
159
bypass to inverter
9999
operation
User group read
160
0, 1, 9999

selection
Frequency setting/key
161
lock operation selection 0, 1, 10, 11
Automatic restart after
162
instantaneous power
0 to 3, 10 to 13 0
failure selection
First cushion time for
163
0 to 20s
restart
First cushion voltage for
164
0 to 100%
restart
Stall prevention
165
0 to 400%
operation level for restart
Output current detection
166
0 to 10s, 9999 0.1s
signal retention time
Output current detection
167
0, 1, 10, 11
operation selection
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
0, 10, 9999
Operation hour meter
171
0, 9999
clear
User group registered
172
9999, (0 to 16) 0
display/batch clear
173
User group registration 0 to 1999, 9999 9999
174
User group clear
0 to 1999, 9999 9999
STF terminal function
178
selection
STR terminal function
179
selection
RL terminal function
180
selection
RM terminal function
181
selection
0 to 8, 10 to 14,
RH terminal function
182
16, 18, 24, 25,
selection
28, 37, 46 to 48,
RT terminal function
50, 51, 57, 58,
183
selection
60 to 62,
64 to 67,
AU terminal function
184
70 to 73,
selection
77 to 81, 84,
JOG terminal function
94 to 98, 9999
185
selection

CS terminal function
186
selection
MRS terminal function
187
selection
STOP terminal function
188
selection
RES terminal function
189
selection
Initial
Pr.
Name
value
RUN terminal function
9999
190
selection
120/110%

SU terminal function
191
selection
150/120%

IPF terminal function
192
selection
120/110%

0s
OL terminal function
193
selection
5%
FU terminal function
194
selection
0.5s
ABC1 terminal function
195
1
selection
ABC2 terminal function
196
0
selection
232 to
Multi-speed setting (8
0
239
speed to 15 speed)
Soft-PWM operation
240
selection
Analog input display
241
unit switchover
1
Terminal 1 added
242
compensation amount
(terminal 2)
Terminal 1 added
9999
243
compensation amount
(terminal 4)
Cooling fan operation
9999/0

244
selection
245
Rated slip
0
Slip compensation time
246
constant
Constant-power range slip
247
compensation selection
0s
Self power
248
management selection
0%
Earth (ground) fault
249
detection at start
120/110%

250
Stop selection
Output phase loss
251
protection selection
0
252
Override bias
253
Override gain
Main circuit power OFF
254
9999
waiting time
Life alarm status
9999
255
display
Inrush current limit
256
circuit life display
Control circuit capacitor
257
life display
Main circuit capacitor
258
60
life display
Main circuit capacitor
259
61
life measuring
PWM frequency
260
0
automatic switchover
Power failure stop
261
1
selection
Subtracted frequency at
262
2
deceleration start
Subtraction starting
263
3
frequency
Power-failure
264
4
deceleration time 1
Power-failure
265
5
deceleration time 2
Power failure deceleration
266
9999
time switchover frequency
267
Terminal 4 input selection 0 to 2
24
Monitor decimal digits
268
selection
25
269
Parameter for manufacturer setting. Do not set.
Inverter output terminal
62
289
filter
Monitor negative output
290
selection
291
Pulse train I/O selection
UV avoidance voltage
294
gain
Frequency change
295
increment amount setting
296
Password lock level
Setting
Initial
Pr.
range
value
0 to 5, 7, 8,
297
Password lock/unlock
0
10 to 19, 25, 26,
35, 39 to 42,
45 to 54, 57,
Frequency search gain 0 to 32767,
298
64 to 68,
1
70 to 80, 82, 85,
Rotation direction
90 to 96,
299
detection selection at
98 to 105, 107,
restarting
2
108, 110 to 116,
125, 126, 135,
139 to 142,
145 to 154, 157,
3
164 to 168,
313
DO0 output selection
170 to 180, 182,
185, 190 to 196,
198 to 208,
4
211 to 213, 215,
217 to 220, 226,
228 to 230, 242,
99
300 to 308,
311 to 313, 315,
314
DO1 output selection
317 to 320, 326,
328 to 330, 342,
9999
9999

0 to 590Hz,
9999
9999
0, 1
1
315
DO2 output selection
0, 1
0
0 to 100%
100%
Communication
338
operation command
source
0 to 100%
75%
Communication speed
339
command source
0, 1, 101 to
1
105
Communication startup
340
mode selection
0 to 50%, 9999 9999
Communication
342
EEPROM write selection 0, 1
0.01 to 10s
0.5s
Communication reset
349
0, 9999
9999
selection
Overspeed detection
374
0 to 2
0
level
Input pulse division
384
0, 1
0
scaling factor
Frequency for zero
0 to 100s,
385
input pulse
1000 to 1100s,
9999
8888, 9999
Frequency for
386
maximum input pulse
0, 1
1
% setting reference
390
frequency
0 to 200%
50%
PLC function operation
0 to 200%
150%
414
selection
1 to 3600s,
600s
Inverter operation lock
9999
415
mode setting
(0 to 15)
0
Pre-scale function
416
selection
(0 to 100%)
100%
417
Pre-scale setting value 0 to 32767
(0 to 100%)
100%
(0 to 100%)
100%
450
Second applied motor
0, 1
0
0, 1
1
0 to 2, 11, 12,
0
21, 22
453
Second motor capacity
0 to 20Hz
3Hz
0 to 590Hz,
Number of second
60/50Hz

454
9999
motor poles
0 to 3600s
5s
Second motor
455
0 to 3600s,
excitation current
9999
9999
Rated second motor
0 to 590Hz
60/50Hz

456
voltage
0
Rated second motor
457
frequency
0, 1, 9999
9999
Second motor constant
458
(R1)
5 to 50ms,
9999
9999
Second motor constant
459
0 to 7
0
(R2)
0, 1, 10, 11, 20,
21, 100
Second motor constant
0
(FM type)
460
(L1) / d-axis inductance
(Ld)
0, 1 (CA type)
0 to 200%
100%
Second motor constant
461
(L2) / q-axis inductance
0, 0.01, 0.10,
0
(Lq)
1.00, 10.00
0 to 6, 99,
Second motor constant
462
100 to 106,
9999
(X)
199, 9999
Second motor auto
463
tuning setting/status
Parameter list
Setting
Initial
Name
range
value
(0 to 5),
1000 to 9998,
9999
9999
9999
9999
0, 1, 9999
9999
0 to 5, 7, 8,
10 to 19, 25, 26,
35, 39 to 42,
9999
45 to 54, 57,
64 to 66, 68,
70 to 80, 85 to
96, 98 to 105,
107, 108, 110 to
116, 125, 126,
135, 139 to 142,
145 to 154, 157,
9999
164 to 166, 168,
170 to 180, 185
to 196, 198 to
208, 211 to 213,
215, 217 to 220,
226, 228 to 230,
242, 300 to 308,
311 to 313, 315,
9999
317 to 320, 326,
328 to 330, 342,
9999
0, 1
0
0 to 2
0
0 to 2, 10, 12
0
0
0, 1
0
0 to 590Hz,
9999
9999
0 to 250
0
0 to 590Hz
0
0 to 590Hz
60/50Hz

1 to 590Hz
60/50Hz

0 to 2
0
0, 1
0
0 to 5
0
1
0, 1, 3 to 6,
13 to 16, 20, 23,
24, 40, 43, 44,
50, 53, 54, 70,
73, 74, 210,
9999
213, 214, 240,
243, 244, 8090,
8093, 8094,
9090, 9093,
9094, 9999
0.4 to 55kW,
9999

9999
0 to 3600kW,
9999

2, 4, 6, 8, 10,
9999
12, 9999
0 to 500A,
9999

9999
0 to 3600A,
9999

0 to 1000V
200/400V

10 to 400Hz,
9999
9999
0 to 50Ω, 9999

9999
0 to 400mΩ,
9999

0 to 50Ω, 9999

9999
0 to 400mΩ,
9999

0 to 6000mH,
9999

9999
0 to 400mH,
9999

0 to 6000mH,
9999

9999
0 to 400mH,
9999

0 to 100%,
9999
9999
0, 1, 11, 101
0
19
BASIC OPERATION

Advertisement

loading