CHAPTER 1. Before Installation
Ambient Conditions
This section describes the operating temperature, humidity level and other ambient
conditions and related standard of RRH-C2A.
The following table shows the ambient conditions and related standard of RRH-C2A.
Item
a)
Temperature
a)
Humidity
Altitude
Vibration
Noise (sound pressure level)
Electromagnetic compatibility
(EMC)
US Federal Regulation
a) Temperature and humidity are measured at 1.5 m (59 in) above the floor and at 400 mm (15.8 in) away
from the front panel of the RRH-C2A.
1-4
-40~55°C (-40~131°F) without solar load
10~95%
The moisture content must not exceed 0.024 kg per 1 kg of air.
0~1,800 m (0~6,000 ft)
GR-63-CORE Sec.4.4
Earthquake
Office Vibration
Transportation Vibration
Max. 65 dBA at distance of 1.5 m (5 ft) and height of 1.0 m (3 ft)
FCC Title47 Part 15 Class B
FCC Title47 Part90
Range