3. Centering Adjustment
[Adjusting Location]
Centering magnet
[Adjustment I Check]
Measuring Point
Measuring Equipment
Viewfinder
Input Signal
(WR5-5CSP): For operation check,
monoscope portion
ADJ. Location
Preparation:
• POWER switch: "PLAYER"
Adjustment:
1 . Turn the centering magnet to center the picture.
2. Fix the centering magnet with lacquer.
11
Condition
Playback
I
Alignment Tape
I
ADJ.
Check Value
- 5-27 -
&
4. Horizontal Size
Viewfinder S lant Adjustment
[Adjusting Location]
Yoke clamp
[Adjustment I Check]
Measuring Point
Measuring Equipment
Viewfinder
Input Signal / Alignment Tape
(WR5-5CSP): For operation check
monoscope portion
ADJ. Location
Preparation:
• POWER switch: "PLAYER"
Adjustment:
1 . Loosen the yoke clamp, then move the deflection coil in
the direction of arrow A, and adjust the horizontal size
within 87.5 to 92.5 on the horizontal size scale of the
monoscope signal.
2. Turn the deflection coil so that picture slant is within
1 .5
(The difference between right and left should be
° .
within 0.5 on the vertical size scale of the monoscope
signal).
3. Fix the deflection coil with the yoke clamp.
Deflection coil
Condition
Playback
I
ADJ.
Check Value