2. VTR B LOCK ADJUSTME NT
2-1 . EQUIPMENTS
TV
1 . Monitor
2. Oscilloscope 2 phenomena, band 1
delay mode. (Use 1 O
fied.)
3. Frequency counter, Universal counter
4. Pattern generator with video output terminal
Note:
One on which the chroma signal can be turned
off)
5. Regulated power supply
6. Alignment tape
7. MP tape, Hi8M P (ME) tape
8. Circuit board connecting tool
9. Alligator clip lead wire
1 0. Extension cord (VJ8-01 42)
1 1 . Adjustment ( - ) screwdriver
Name
Video frequency
characteristics
(WR5 - 7CE)
Operation check
(WR5-5CSP/9CS)
Operation check (Hi8)
(WR5-8CSE)
Circuit board connecting tool
o
MHz or wider,
:
1 probe unless otherwise speci­
1 . Recorded area
2. Recorded contents
3. Marker
1 . Recorded area
2. Recorded contents
1 . Recorded area
2. Recorded contents
2-2. ALIGNMENT TAPE
For video frequency characteristics adjustment
(WR5-7CE) :
For operation check
(WR5-5CSP) : Part code; 96-7995-47
For operation check
(WR5-9CS) :
For operation check
(WR5-8CSE) : Part code; 96-7995-48
The initial "8" of the parts code for the alignment tape
Note:
has been omitted. Parts codes with and without this
initial "8" are identical.
Contents
Video
RF sweep 0 to 1 5 MHz
2, 4.5, 7.0, 8.5, 1 0.0 MHz
Video, PCM
Color bar, monoscope (SP)
Audio signal (FM), PCM audio signal
Video, PCM
Color bar, monoscope (SP)
Audio signal (FM), PCM audio signal
WR5-5CSP, WR5-7CE, WR5-8CSE, WR5-9CS
- 5- 1 1 -
Part code; 96-7995-1 8
Part code; 96-7995-28
Application
Frequency characteristics
adjustment
Operation check
Operation check