10D1475 MINI-MAG MAGNETIC FLOWMETER INSTRUCTION BULLETIN
Environmental Limits
Enclosure Classification with
or without Signal Converter
Accidental Submergence
Continuous Submergence
Ambient Temperature Limits
Process Limits
Temperature Limits
Signal Converter must be remote mounted if liquid temperature ex-
ceeds value listed for a given ambient temperature. Liquid tem-
perature must not exceed 250
Pressure
INTRODUCTION
NEMA 4X, IEC 529 IP65
IEC 529 IP67, 30 feet H
IEC 529 IP68, 30 feet H
MODEL
10D1475H
w/ Integral Converter
10D1475H/J
w/ Remote Converter
NOTE
Temperature
o
o
F
C
100
40
150
65
250
120
O/48 h (9 m H
2
O (9 m H
2
LIMITS
o
-4 to 131
F
o
(-20 to 55
C)
o
-40 to 150
F)
o
(-40 to 65
C)
o
o
F (121
C) in any event.
Pressure
psi
MPa
740
5.11
720
4.96
650
4.50
O /48 h)
2
O)
2
1-9