12B
Upon completion, the user is asked if they want to install
ActiveSync. If the local connection on the NGC is USB, the user
will need ActiveSync. The user may already have ActiveSync
installed if they communicate with a PDA device. If the user has
ActiveSync and it is an older version, checking the Install
ActiveSync box will give them the opportunity later in the install
procedure to update their current version.
12C
A subsequent option screen will enable the user to select the
local port used for the local connection. If the wrong choice is
made, it can be changed later in PCCU's System Setup.
Use USB Port – Select if connecting through USB. This is
the outside connector on the NGC with an explosion-proof
cap.
Use Serial Port – If using the serial port, the external
connection on the NGC is a round, military type connector.
Keep Current Port – If PCCU is currently installed on the
computer and the user is upgrading to a newer version,
select this option to keep the current local port setup.
Step 13
Connect Local Communications Cable
The local communication cable will either have a USB connector or a
RS-232 military style connector on the NGC end. Connect to the
appropriate communication port on the PC (default is COM1). If the user
elects to employ the USB and receives a dialog box asking to set up a
partnership, click the Cancel button. On the next screen, click OK and
then the Close button on the third screen.
USB Cable P/N 1801800-xxx
MMI Cables
RS-232 Cable P/N 2015240-xxx
7