RRU3203
Installation Guide
Connect the M6 OT terminal at one end of the PGND cable to the ground terminal at the RRU
bottom and the M8 OT terminal at the other end to the external ground bar, as shown in
8-6.
Figure 8-6 Installing an RRU PGND cable
Crimp OT terminals in correct positions, as shown in
Figure 8-7 Correct position of an OT terminal
Step 3 Label the installed cable by referring to Attaching a Cable-Tying Label.
----End
8.6 Installing an RRU RF Jumper
This section describes the procedure for installing an RRU RF jumper.
Procedure
Step 1 Link the DIN connector at one end of the RF jumper to the ANT port and use a torque wrench
to tighten the connector to 25 N·m (221.27 lbf·in.), as shown in
Issue 06 (2012-04-16)
NOTE
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Figure
8-7.
Figure
8 Installing RRU Cables
Figure
8-8.
71