NEC Express5800 Series Maintenance Manual page 195

Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
Error
Class
code
UEFI
411
UEFI
414
UEFI
415
UEFI
420
UEFI
421
UEFI
422
UEFI
423
UEFI
424
UEFI
430
UEFI
431
UEFI
432
Error message
Innovation Engine Error - The Innovation
Engine is operating in recovery mode.
Server Platform Services Firmware Error -
The SPS Firmware is not operating
properly. (Error Code %1).
IMPORTANT: The Innovation Engine
Firmware revision in this system does not
meet minimum requirements for operation
with NVDIMMs. All NVDIMM functionality
has been disabled.
TLS certificate verification error 0x%1 while
downloading from %2:%3.
TLS certificate verification failed due to
hostname mismatch.
TLS certificate verification failed. The
passed certificate is self-signed and the
same certificate cannot be found in the list
of trusted certificates.
TLS certificate verification failed. The
issuer certificate of a looked up certificate
could not be found. This normally means
the list of trusted certificates is not
complete.
No TLS certificate enrolled. At least one
certificate authority must be enrolled when
TLS verification mode is set to PEER.
Scalable Persistent Memory uncorrectable
memory error on %1 Logical NVDIMM %2.
The memory region will not be available to
the OS and data may have been lost.
Scalable Persistent Memory backup failed
on %1 Logical NVDIMM %2. Persistent
data has been lost.
Scalable Persistent Memory restore failed
for %1 Logical NVDIMM %2. Persistent
data may have been lost.
Express5800/R120h-1E, R120h-2E Maintenance Guide
Action
Set the maintenance switch SW12 to OFF unless the
setting is specified in the operating procedure etc.
When operating the maintenance switch, follow the
procedure in Chapter 1 (7. Resetting and Clearing the
Server) in this manual.
If the problem persists, contact your sales
representative.
Updating the latest server platform service firmware
may solve the error. Please update the server platform
service firmware.
If the problem persists, contact your sales
representative.
Updating the latest Innovation Engine Firmware may
solve the error. Please update the Innovation Engine
Firmware.
If the problem persists, contact your sales
representative.
Register the certificate required for authentication, and
check the TLS setting.
Check whether the certificate required for authentication
has been registered, or check the TLS setting.
Check whether the certificate required for authentication
has been registered, or check the TLS setting.
Check whether the certificate required for authentication
has been registered, or check the TLS setting.
Register the certificate required for authentication, and
check the TLS setting.
Contact your sales representative.
Contact your sales representative.
Contact your sales representative.
1. IML Error Message