HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description
Figure 3-11 Architecture of the CX600-X16 AC power supply system
AC1
AC1"
Installing the EPS200-4850A in the same cabinet as the chassis is recommended. If the
EPS200-4850A cannot be installed in the same cabinet as the chassis, it should be placed near
the cabinet and careful attention needs to be paid to the cabling. Two EPS200-4850A work in
1+1 backup mode. Each power module provides four circuit breakers and eight AC power inputs.
Each circuit breaker is 20 A.
3.3 Heat Dissipation System
This section describes the appearance, functions, and specifications of the heat dissipation
system.
3.3.1 System Air Channel
This section describes the CX600-X16's system air channel.
The CX600-X16 is divided into an upper chassis and a lower chassis; it draws in air from the
front and exhausts air from the rear. The air intake vent on the upper chassis is located above
the board area on the front chassis; the air exhaust vent is located above the board area on the
rear chassis. The lower chassis and the upper chassis are opposites. The upper chassis and the
lower chassis also have separate heat dissipation systems.
Issue 03 (2013-11-30)
AC2
AC4
AC3
DC a1
DC b1
DCa
DC a2
DC b2
DC a3
DCb
DC b3
DC a4
DC b4
Power module
AC3"
AC2"
AC4"
NOTE
PEM A1 and PEM B1 work in 1+1 backup mode, PEM A2 and PEM B2 work in 1+1 backup mode, PEM
A3 and PEM B3 work in 1+1 backup mode, PEM A4 and PEM B4 work in 1+1 backup mode.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
PEM A1
area 1
PEM B1
PEM A2
area 2
PEM B2
PEM A3
area 3
PEM B3
PEM A4
area 4
PEM B4
Backplane
3 CX600-X16
FAN
FAN
SFU
SFU
SFU
SFU
FAN
FAN
FAN
Boards
Boards
Boards
FAN
43