Item
Input voltage range
Maximum input current
Maximum output current
Maximum output power
The following figure shows the indicators on the EPS200-4850A.
Figure 3-10 Indicators on the EPS200-4850A
1. Operation indicator
The following table provides the checklist for the EPS200-4850A.
Item
Operation
indicator
Issue 03 (2013-11-30)
Technical Parameter
90 V AC to 275 V AC
175 V AC to 275 V AC (recommended)
18.5 A/single module
50 A/single module
2900 W/single module
2. Protection indicator
Indicator
Status Description
Color
Green
If the indicator is
steady green, the
EPS200-4850A is
running properly. If the
indicator is off, an
exception occurs.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 CX600-X16
3. Fault indicator
Cause of the Abnormality
No main AC power is input, the
AC input voltage is higher or
lower than the normal range, or
the EPS200-4850A has no
output.