Samsung SCP-3371/SCP-3371H User Manual page 78

Speed dome camera
Table of Contents

Advertisement

setup
M
Connecting the power connector and GND incorrectly to the NC/NO and COM ports may cause a short circuit and fi re,
damaging the camera.
The maximum power capacity of the built-in relay is 30VDC/2A, 125VAC/0.5A, and 250VAC/0.25A. Operating the
camera beyond the capacity may decrease the camera's lifespan and damage it.
MD Dwell Time
When Motion Detection under the Preset Edit menu is selected,
MD Dwell Time performs the Tour or Group function.
While the camera is performing a sequence action, if motion is
detected from a selected preset location, the camera pauses the
sequence action operation and starts monitoring the location instead
for a duration that is set under the MD Dwell Time menu.
If the motion is no longer detectable or the duration expires, the
camera aborts the monitoring operation and then resumes the
sequence action.
ALM Dwell Time
You can specify the time of sequence operation that will be activated if an event occurs from the alarm
input.
SET:
The sequence operation will proceed for a specifi ed time.
HOLD:
The sequence operation will be maintained until the user deactivates it.
78_
setup
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Password Setting
Status
Alarm Setting
Alarm Enable
Alarm Input
Alarm/AUX Output
MD Dwell Time
ALM Dwell Time
OFF
OFF
HOLD