Error Codes - GE Bently Nevada 3300/25 Operation Manual

Dual accelerometer input monitor
Table of Contents

Advertisement

3300/25 Dual Accelerometer Input Monitor Operation Manual
Refer to the Monitor Functions,
about displaying error codes. Refer to the Self Test section for information about clearing
stored errors.
ERROR
DESCRIPTION
CODE
2
ROM checksum failed.
3
Nonrecoverable EEPROM failure. Tested only at Cyclic self test. Install your
4
EEPROM failure.
5
+7.5V/-VT node out of tolerance.
6
+VRH node out of tolerance.
7
+5V node out of tolerance.
8
MVREF node out of tolerance.
9
+7.5V node out of tolerance.
10
+VRL node out of tolerance.
11
MVREF/-6.5V node out of
tolerance.
12
+5V/-7.5V node out of tolerance.
13
Clock OK voltage out of
tolerance.
14
RAM failure.
17
COP watchdog not configured.
NOTE: If the monitor experiences recurring stored errors contact your local Bently
Nevada office for service.
46

17. Error Codes

Section 2
and Self Test,
EXPLANATION/RECOVERY
Tested at power up and User-invoked self
test. This error is displayed on the front
panel, but is not stored in memory. Install
your spare monitor or contact your local
Bently Nevada office for service.
spare monitor or contact your local Bently
Nevada office for service.
May be corrected by adjusting alarm
setpoints in the monitor
If setpoint adjustment fails to correct this
error, install your spare monitor or
contact your local Bently Nevada office
for service.
Tested cyclically. If it is a stored error,
recall and clear the error codes as
described in the Self Test,
If it is an active error, replace the monitor
with a spare or contact your local Bently
Nevada office for service.
Tested only at Power-up or User-invoked
self test. These errors are displayed on
the front panel but not stored in memory.
Install your spare monitor or contact your
local Bently Nevada office for service.
Section 16
for more information
(See section
Section
10).
16.