Indoor Air Quality Inside a Building is Optimized Through
Temperature and Humidity Exchange by Lossnay
Lossnay is a total heat exchange ventilation system that uses paper
characteristics to perform temperature (sensible heat) and humidity
(latent heat) exchange.
The concept of sensible heat and latent heat exchange
using a Lossnay core
Outside
Exhaust air outlet (EA)
Outdoor air intake (OA)
What can be Improved by Introducing Lossnay?
• Ventilation with maximized comfort
In summer
Air similar to the conditions of cooled (dehumidified)
indoor air is supplied.
Supply air
Lossnay
Dry bulb temperature (ºC)
28
Absolute humidity (g/kg'(DA))
13.3
Relative humidity (%)
56
Enthalpy (kJ/kg(DA))
62.1
Total energy recovery (kW)
7.5
Outdoor air load (kW)
3.1
Outdoor air load ratio (%)
29
Return air
Dry bulb temperature
26ºC
Absolute humidity
10.5g/kg'(DA)
Air
conditioner
Relative humidity
Enthalpy
52.9kJ/kg(DA)
Indoor supply air
Outdoor
Outdoor
_
=
temperature (ºC)
temperature (ºC)
temperature (ºC)
Calculation example: 28ºC = 33ºC _ (33ºC _ 26ºC) × 71.5%
*The above applies to LGH-100RVX (fan speed 4).
Inside
Return air (RA)
Supply air (SA)
Conventional
ventilator
33
20.1
Exhaust air
63
84.6
0
10.6
100
Outdoor air
Dry bulb temperature
33ºC
Absolute humidity
20.1g/kg'(DA)
50%
Relative humidity
63%
Enthalpy
84.6kJ/kg(DA)
Indoor
Temp. recovery
_
×
temperature (ºC)
efficiency (%)
LGH-RVX/RVXT Series / GUF Series
Lossnay ventilation systems are renowned
industry-wide for their efficiency.
They offer environmentally friendly energy
recovery and humidity control, and enable
air-conditioning systems to simultaneously
provide optimum room comfort and energy
savings.
EA
OA
In winter
Air similar to the conditions of heated (humidified)
indoor air is supplied.
Supply air
Lossnay
Dry bulb temperature (ºC)
16
Absolute humidity (g/kg'(DA))
5.2
Relative humidity (%)
46
Enthalpy (kJ/kg(DA))
29.2
Total energy recovery (kW)
8.2
Outdoor air load (kW)
3.1
Outdoor air load ratio (%)
28
Return air
Dry bulb temperature
Absolute humidity
7.3g/kg'(DA)
Air
conditioner
Relative humidity
Enthalpy
38.5kJ/kg(DA)
Indoor supply air
Indoor
_
=
temperature (ºC)
temperature (ºC)
Calculation example: 16ºC = (20ºC _ 0ºC) × 80% + 0ºC
*The above applies to LGH-100RVX (fan speed 4).
SA
Conventional
ventilator
0
1.9
Exhaust air
50
4.7
0
11.3
100
Outdoor air
20ºC
Dry bulb temperature
Absolute humidity
1.9g/kg'(DA)
50%
Relative humidity
Enthalpy
4.7kJ/kg(DA)
Outdoor
Temp. recovery
Outdoor
×
+
temperature (ºC)
efficiency (%)
temperature (ºC)
183
RA
0ºC
50%

Advertisement

loading

This manual is also suitable for:

S seriesWy seriesR2 seriesWr2 series