Mitsubishi Electric MSZ-AP22VGD Operating Instructions Manual

Mitsubishi Electric MSZ-AP22VGD Operating Instructions Manual

Indoor unit

Advertisement

SPLIT-TYPE AIR CONDITIONERS
INDOOR UNIT
MSZ-AP22VGD MSZ-AP25VGD MSZ-AP35VGD MSZ-AP42VGD MSZ-AP50VGD
MSZ-AP22VGKD MSZ-AP25VGKD MSZ-AP35VGKD MSZ-AP42VGKD MSZ-AP50VGKD
OPERATING INSTRUCTIONS
• To use this unit correctly and safely, be sure to read these operating
instructions before use.
For user
English

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric MSZ-AP22VGD

  • Page 1 SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT MSZ-AP22VGD MSZ-AP25VGD MSZ-AP35VGD MSZ-AP42VGD MSZ-AP50VGD MSZ-AP22VGKD MSZ-AP25VGKD MSZ-AP35VGKD MSZ-AP42VGKD MSZ-AP50VGKD For user OPERATING INSTRUCTIONS • To use this unit correctly and safely, be sure to read these operating English instructions before use.
  • Page 2 ● OPERATING INSTRUCTIONS ● ONTENTS I SAFETY PRECAUTIONS I NAME OF EACH PART I PREPARATION BEFORE OPERATION I SELECTING OPERATION MODES I FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT I I-SAVE OPERATION I ECONO COOL OPERATION I NIGHT MODE OPERATION I TIMER OPERATION (ON/OFF TIMER) I WEEKLY TIMER OPERATION I DEMAND RESPONSE AND INDOOR UNIT OPERATION (MUZ-VGD TYPE ONLY) I EMERGENCY OPERATION...
  • Page 3: Safety Precautions

    AFETY PRECAUTIONS This appliance is not intended for use by persons (including children) Before cleaning the unit, switch it OFF and disconnect the power plug with reduced physical, sensory or mental capabilities, or lack of ex- or turn the breaker OFF. •...
  • Page 4: For Installation

    ● OPERATING INSTRUCTIONS ● AFETY PRECAUTIONS For installation For Wi-Fi interface WARNING WARNING (Improper handling may have serious consequences, including serious injury or death.) Consult your dealer for installing the air conditioner. • It should not be installed by the user since installation requires specialized This appliance can be used by children aged from 8 years and above knowledge and skills.
  • Page 5: Indoor Unit

    AME OF EACH PART Indoor unit Remote controller Battery replacement indicator Signal transmitting Page 5 Front panel section Distance of signal : Operation dis- Air inlet About 6 m play section Beep(s) is (are) heard from Wi-Fi interface the indoor unit when the Page 13 signal is received.
  • Page 6: Preparation Before Operation

    ● OPERATING INSTRUCTIONS ● REPARATION BEFORE OPERATION Before operation: Insert the power supply plug into the power outlet and/or Setting current time turn the breaker on. Press the DAY button Installing the remote controller batteries to set the day. Press RESET. Press CLOCK.
  • Page 7: Selecting Operation Modes

    ELECTING OPERATION MODES DRY mode Dehumidify your room. The room may be cooled slightly. Temperature cannot be set during DRY mode. HEAT mode Enjoy warm air at your desired temperature. FAN mode Circulate the air in your room. Note: After COOL/DRY mode operation, it is recommended to operate in the FAN mode to dry inside the indoor unit.
  • Page 8 ● OPERATING INSTRUCTIONS ● AN SPEED AND AIRFLOW DIRECTION ADJUSTMENT Up-down Airflow direction Press to select airfl ow direction. Each press changes airfl ow direction in the following order: (AUTO) (SWING) (AUTO) ..The vane is set to the most effi cient airfl ow direction. COOL/ DRY/FAN: horizontal position.
  • Page 9: Save Operation

    SAVE OPERATION CONO COOL OPERATION A simplifi ed set back function enables to recall the preferred (preset) Swing airfl ow (change of airfl ow) makes you feel cooler than station- setting with a single push of the button. Press the button again ary airfl...
  • Page 10 ● OPERATING INSTRUCTIONS ● IGHT MODE OPERATION IMER OPERATION (ON/OFF TIMER) NIGHT MODE changes the brightness of the operation indicator, disables the beep sound and limits the noise level of the outdoor unit. Press during operation to set the timer. (ON timer) : The unit turns ON at the set time.
  • Page 11: Weekly Timer Operation

    EEKLY TIMER OPERATION • A maximum of 4 ON or OFF timers can be set for individual days of the week. • A maximum of 28 ON or OFF timers can be set for a week. Press , and to set ON/OFF, time, and temperature.
  • Page 12: Emergency Operation

    ● OPERATING INSTRUCTIONS ● EMAND RESPONSE AND INDOOR UNIT OPERATION (DEMAND TYPE ONLY) Demand response This unit has demand response capability which is compliant with AS/NZS 4755.3.1. To activate this function, you need to make a contract with remote agents such as electric supply company, then this unit should be connected to Demand response enabling devise (DRED).
  • Page 13: Front Panel

    LEANING Instructions: • Switch off the power supply or turn off the breaker before cleaning. • Do not soak or rinse the horizontal vane. • Be careful not to touch the metal parts with your hands. • Do not use water hotter than 50°C. •...
  • Page 14 ● OPERATING INSTRUCTIONS ● i-Fi INTERFACE SETTING UP (VGK TYPE ONLY) This Wi-Fi interface, communicates the status information and controls Information for users the commands from the server by connecting to the indoor unit. The following steps explain how to connect the Wi-Fi interface to a Router. KEY (LED LIGHTS): : ON : OFF...
  • Page 15: Led Pattern

    i-Fi INTERFACE SETTING UP (VGK TYPE ONLY) Once completed, the MAC and ID will be fi lled in Open Wi-Fi Control App. Enter MAC and ID into ‘Add new unit’. Select ‘Add’ and then control your ‘Add new unit’ and select ‘Add’. heat pump via Wi-Fi.
  • Page 16: Troubleshooting

    If a problem regarding connecting your Router and the Wi-Fi interface persists, www.mitsubishi-electric.co.nz/wifi please contact your local Mitsubishi Electric offi ce, as listed on the back of this Phone: 0800 639 434 guide. A list of compatible Routers is also available.
  • Page 17: When You Think That Trouble Has Occurred

    HEN YOU THINK THAT TROUBLE HAS OCCURRED Symptom Explanation & Check points Even if these items are checked, when the unit does not recover from the Remote controller trouble, stop using the air conditioner and consult your dealer. The display on the remote •...
  • Page 18: Electrical Work

    ● OPERATING INSTRUCTIONS ● HEN YOU THINK THAT TROUBLE HAS OCCURRED In the following cases, stop using the air conditioner and consult your dealer. • When water leaks or drips from the indoor unit. • When the operation indicator lamp blinks. •...
  • Page 19: Specifications

    PECIFICATIONS Guaranteed operating range Indoor Outdoor 32°C DB 46°C DB Upper limit 23°C WB — Cooling 21°C DB -10°C DB Lower limit 15°C WB — 27°C DB 24°C DB Upper limit 18°C WB — Heating 20°C DB -15°C DB Lower limit -16°C WB —...
  • Page 20 HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN JG79Y333H01...

Table of Contents