Wireless Remote Controller
PAR-FL32MA
Dimensions: 58(W) x 159(H) x 19(D) mm
: 2-5/16(W) x 6-5/16(H) x 3/4(D) in.
PAR-SE9FA-E
(4-way cassette signal receiver)
Dimensions: 273(H) x 29(D) mm
• No need to configure addresses for group operation.
• The LED remains lit to show operation status. It also provides error information via the number of blinks.
• Can be used with the MA remote controller.
*When used in group configurations, wiring is required between indoor units.
*ME remote controller and/or Lossnay remote controller cannot be combined in the same group.
• Multiple indoor units cannot be controlled with the PAR-SL100A-E.
Only one indoor unit can be used in each group.
• LCD temperature setting and display in 1°C/1°F increments.
• System configuration example
Non-polarized
2-wire
Signal
receiving
unit
Wireless
remote
controller
PAR-FA32MA
Compatibility table (VRF)
PMFY-P*VBM
PLFY-P*VLMD
PEFY-P*VMR-E/VMH(S)
PFFY-P*VLEM/VKM/VLRM/VLRMM
PEFY-P*VMS1(L)
PEFY-P*VMA(3)(L)
• Functions
Item
ON and OFF operation for a single group
ON/OFF
Changes the set temperature.
Temperature setting
* Set temperature range varies depending on the indoor unit model.
Air flow direction angles (4-angle, Swing) Auto Louver ON/OFF.
Air flow direction setting
Air flow direction settings vary depending on the model.
One ON/OFF setting can be set per day.
Timer operation
Individually prohibit operation of each local remote control function (ON/OFF, Change operation mode, Set
temperature, Reset filter).
Permit / Prohibit local operation
*1 If operation is performed when the local remote controller inactivation command is received from the main system
controller, a buzzer will sound and an LED will flash.
Up to 16 indoor units can be connected to an interlocked system that has one Lossnay.
Ventilation equipment
The Lossnay will run in interlock with the operation of the indoor unit. *2 The fan rate and mode cannot be changed.
Some models will have a different display for the air flow direction and fan speed. Set the air flow direction and fan speed when performing initial settings.
PAR-SL100A-E
(PLFY-P/WL VEM, PLFY-P/WL VFM, PKFY-P/WL VLM/VKM only)
Dimensions: 66(W) x 188(H) x 22(D) mm
: 2-5/8(W) x 7-13/32(H) x 7/8(D) in.
PAR-SF9FA-E
(2 x 2 cassette signal receiver)
Dimensions: 214(H) x 25.5(D) mm
Signal
receiving
unit
PAR-SL94B-E
Signal
receiving
unit N/A
Wireless
remote
controller
PAR-SL100A-E
PAR-SL94B-E
Receiver
Transmitter
PAR-FA32MA
PAR-FL32MA
INDIVIDUAL REMOTE CONTROLLER
Dimensions: 70(W) x 120(H) x 22.5(D) mm
(Wireless remote controller kit for ceiling suspended type)
Compatibility table (HVRF)
PEFY-WP*VMS1
PAR-SF9FA-E
PAR-SE9FA-E
PEFY-W*VMS
PEFY-WP*VMA
Indoor unit
PEFY-W*VMA(L)(2)
grouping
N/A
PFFY-WP*VLRMM
PFFY-W*VCM
PLFY-WL*VEM
Wireless
remote
PLFY-WL*VFM
controller
PKFY-WL*VLM/VKM
PCFY-P*VKM
PKFY-P*VKM
PKFY-P*VLM
PLFY-P*VEM
PLFY-P*VFM-E1
Description
PAR-FA32MA
: 2-3/4(W) x 4-3/4(H) x 7/8(D) in.
PAR-SL94B-E
Dimensions: 182(W) x 57(H) x 31(D) mm
Receiver
Transmitter
PAR-FA32MA
PAR-FL32MA
PAR-SE9FA-E
PAR-SL100A-E
PAR-SF9FA-E
Built-in
Receiver
Transmitter
PAR-FA32MA
PAR-SL94B-E
PAR-FL32MA
Built-in
Built-in
PAR-SE9FA-E
PAR-SL100A-E
PAR-SF9FA-E
: Each group
: Not available
Operations Display
X
*2
X
199
*1
X