CCS Technical Documentation
RX DtoS Balance Calibration
•
Extra equipment / external RF signal not needed
•
RX Dtos Balance Calibration starts at EGSM (GSM900), then continues
at GSM1800 band
•
This Calibration is used for calibrating DSP control words values.
Select Tuning => GSM => Rx DtoS Balance Calibration
NOTE! No RF-input is allowed to feed when calibrating !
Choose "OK" and "Start", tuning begins automatically at the EGSM900 band.
Press "Start"
Issue 1 11/03
Copyright Nokia. All rights reserved..
NHM-1