NHM-1

Energy Management Tuning

External power supply needed
EM Calibration is used for calibrating Battery and Charger settings of the phone.

Preparation for EM Calibration:

- Connect DC Cable SCB-3 between JBV-1 and Vin of Phone for
Charger calibration.
- Connect 12...15 V from Power Supply to JBV-1.
- NOTE! Check that connection is F-BUS (doesn't work with M-BUS!).
Select Tuning => Energy Management Calibration
Energy Management values to be calibrated are checked
Select "Read from Phone" to show current values in phone memory and to check that
the communication with phone works.
Select "Calibrate" to run selected calibrations