6.2.11 Restoring Factory Settings

This topic describes how to restore factory settings for the SmartLogger on the monitoring
panel. After this operation, all parameters, excluding the current date and time, will restore to
the default factory settings. However, the running information, alarm records, and system logs
do not change.
Issue 04 (2013-12-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Operation Procedure
9. Press
, select NetEco, and press
10. Set Connect Mode, NetEco IP, and Port
Number, and press
When Connect Mode is set to Server, the
NetEco connects to the SmartLogger as a
client. Generally, this mode applies to the
scenario where the SmartLogger and
NetEco are in the same local area network
(LAN).
When Connect Mode is set to Client, set
an IP address and a port ID (16100 by
default) for the NetEco on the
SmartLogger. This mode applies to remote
access scenarios, for example, when the
SmartLogger and NetEco are not in the
same LAN.
When Connect Mode is set to
Server+Client, the SmartLogger connects
to the NetEco as a client or connects to a
third-party EMS as a server. The
SmartLogger can connect to a third-party
EMS and Huawei NetEco by Modbus and
TCP. In this way, customers can perform
centralized monitoring by using a
third-party EMS while using Huawei
NetEco to perform remote upgrade, log
uploading, batch parameter setting,
historical performance data analysis, and
historical alarm analysis.