56 Maintenance

Replacing cooling fan in SBU

Procedure

1. Stop, de-energize and ground the drive following the steps in section Shutting down
the drive for maintenance before you start the work.
2. Switch off the motor starter of the fan unit to isolate the fan unit from the
auxiliarypower supply. To identify the motor starter, see the
Diagram of SBU
.
3. Disconnect the wires on the PT, remove the screws that fix the PT, move out the PT
from cabinet.
4. Remove 2 safety blocks on the middle plate, remove the eight hex-head combination
screws (M6x12) that attach the horizontal plate, move out the horizontal plate.
5. Remove the four hex-head combination screws (M6x12) that attach the vertical plate,
move out the vertical plate.
6. Disconnect the wires on the fan kit, remove the screws that fix the fan kit, move out the
fan kit from cabinet.