4.5

CC-Link function setting

4.5.1

Station number setting (Pr.542)

Use Pr.542 Communication station number (CC-Link) to set station number of the inverter. Set this parameter within the
range of 1 to 64.
Pr.
542
Communication station number (CC-Link)
NOTE
• Use different station numbers for different devices. (If different devices have the same station number, the communication
cannot be performed properly.)
 Connection example
Programmable controller
CC-Link
master module
(occupies one station)
Station 00
Name
1
Inverter No.1
remote I/O station
(FR-A8NC)
Remote device station
Station 01
Initial value
Setting range
1 to 64
Inverter No.2
(FR-A8NC)
Remote device station
Station 02
Station 03
Number of stations connected is 4
Inverter No.3
(FR-A8NC)
Remote device station
Station 04
INVERTER SETTING