Device no.
Signal
Frequency setting completion/torque
RXE
command setting completion
(RAM, EEPROM)
Instruction code execution
RXF
completion
RX16
- (NET Y3 function)
RX17
- (NET Y4 function)
RX1A
Error status flag
RX1B
Remote station ready
*1
Signal names are initial values. Using Pr.190 to Pr.196, you can change output signal functions.
For the details of Pr.190 to Pr.196, refer to the FR-E800 Instruction Manual (Function).
*2
Signals are not assigned in the initial setting. Use Pr.313 to Pr.315 to assign signals to the devices RX9 to RXB.
The settings of Pr.313 to Pr.315 are the same as those of Pr.190 to Pr.196 (output terminal function selection).
For the details of Pr.190 to Pr.196, refer to the FR-E800 Instruction Manual (Function).
*3
The signals are fixed. They cannot be changed using parameters.
After "1" is set in the frequency setting command/torque command (RYE) and the
frequency setting command/torque command is written to the inverter RAM and
EEPROM, "1" is set in this signal. When "0" is set in the frequency setting command/
torque command (RYE), "0" is set in this signal.
Under Real sensorless vector control or PM sensorless vector control, the following
value is also written to RAM and EEPROM at the same time.
• During torque control: Torque command value
• During speed control: Torque limit value
After "1" is set in the instruction code execution request (RYF) and the processes
corresponding to the instruction codes (RWw2, 10, 12, 14, 16 and 18) are executed,
"1" is set in this signal. When "0" is set in the instruction code execution request (RYF),
"0" is set in this signal.
*1
The function assigned to Pr.195 is activated.
*1
The function assigned to Pr.196 is activated.
When an inverter error occurs (protective function is activated), "1" is set in this signal.
When the inverter goes into the ready status upon completion of initial setting after
power-on or hardware reset, "1" is set in this signal.
When an inverter error occurs (protective function is activated), "0" is set in this signal.
The signal is used as an interlock signal during the write to/read from the master
module.
Description
DETAILS OF INPUT AND OUTPUT SIGNALS
7
65