Read/
Item
write
Read
Parameter
Write
Fault record batch clear
Write
All parameter clear
Write
Inverter reset
Write
Read
Link parameter extended
*6
setting
Write
Instruction
code
• Refer to the instruction codes in the FR-E800 Instruction Manual (Function) to read/
write parameters as required.
H00 to H63
Write to Pr.77 and Pr.79 is disabled.
When setting Pr.100 and later, set link parameter extended setting.
• Set 65520 (HFFF0) as a parameter value "8888" and 65535 (HFFFF) as "9999".
• When changing the parameter values frequently, set "1" in Pr.342 to write them to the
RAM. For details, refer to the FR-E800 Instruction Manual (Communication).
H80 to HE3
HF4
H9696: Clears the fault records as a batch.
All parameters return to the initial values. Whether to clear communication parameters
or not can be selected according to data.
Refer to the FR-E800 Instruction Manual (Communication) for Parameter clear, All
parameter clear, and communication parameters.
• Parameter clear
H9696: Communication parameters are cleared.
*5
HFC
H5A5A
: Communication parameters are not cleared.
• All parameter clear
H9966: Communication parameters are cleared.
*5
H55AA
: Communication parameters are not cleared.
When clear is executed for H9696 or H9966, communication-related parameter
settings also return to the initial values. When resuming operation, set the parameters
again. Executing clear will clear the instruction code HEC, HF3, and HFF settings.
HFD
H9696: Resets the inverter.
Parameter settings are changed according to the instruction code settings. For the
H7F
details of setting values, refer to the instruction codes in the parameter list of the FR-
HFF
E800 Instruction Manual (Function).
Description
DETAILS OF INPUT AND OUTPUT SIGNALS
7
75