Program Example For Parameter Reading - Mitsubishi Electric 800 Series Instruction Manual

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

8.5

Program example for parameter reading

The following program reads Pr.7 Acceleration time of station 1 inverter to D1.
• Pr.7 Acceleration time reading instruction code: H07 (hexadecimal)
• For the instruction codes of parameters, refer to the FR-E800 Instruction Manual (Function).
• The reply code at the time of instruction code execution is set to D2. (Refer to
X0
X0F
X1
0
M0
X20
7
M300
11
M301
X100F
13
M302
X100F
20
28
NOTE
• For parameters having numbers 100 and later, change their link parameter extended settings (set them to other than H00).
For the setting values, refer to the parameter list of the FR-E800 Instruction Manual (Function).
88
PROGRAMMING EXAMPLES
SW80.0
MOV H7
MOV W3
MOV W2
page
M0
Check the data link status of the station 1
PLS M300
SET M301
W102
Write Pr.7 read code (H07) to RWw2.
Turn on the instruction code execution request (RY0F)
SET Y100F
RST M301
SET M302
D1
Read acceleration time (RWr3) and reply code
(RWr2) to D1 and D2 when the instruction code
execution completion (RX0F) turns on.
D2
RST Y100F
Turn off the instruction code execution request (RY0F)
RST M302
END