Mitsubishi Electric 800 Series Instruction Manual page 84

Rs-485 interface board, rs-485 communication terminals
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Pr.
Register
42122
Terminal 4 bias (torque/magnetic flux)
C39 (932)
Terminal 4 bias (torque/magnetic flux)
43932
(terminal analog value)
C40 (933)
41933
Terminal 4 gain command (torque/magnetic flux)
42123
Terminal 4 gain (torque/magnetic flux)
C41 (933)
Terminal 4 gain (torque/magnetic flux)
43933
(terminal analog value)
C42 (934)
41934
PID display bias coefficient
42124
PID display bias analog value
C43 (934)
PID display bias analog value
43934
(terminal analog value)
C44 (935)
41935
PID display gain coefficient
42125
PID display gain analog value
C45 (935)
PID display gain analog value
43935
(terminal analog value)
For details on parameter names, refer to the
1000 to
45000 to
parameter list (the Instruction Manual
1999
45359
(Detailed) of the inverter).
• Faults history
Register
40501
Faults history 1
40502
Faults history 2
40503
Faults history 3
40504
Faults history 4
40505
Faults history 5
40506
Faults history 6
40507
Faults history 7
40508
Faults history 8
Name
Definition
Read/Write
Read
Read
Read
Read
Read
Read
Read
Read/write
Read/Write
Analog value (%) set to C39 (932)
Analog value (%) of current (voltage) applied to
Read
terminal 4
Read/Write
Read/Write
Analog value (%) set to C41 (933)
Analog value (%) of current (voltage) applied to
Read
terminal 4
Read/Write
Read/Write
Analog value (%) set to C43 (934)
Analog value (%) of current (voltage) applied to
Read
terminal 4
Read/Write
Read/Write
Analog value (%) set to C45 (935)
Analog value (%) of current (voltage) applied to
Read
terminal 4
The parameter number + 44000 is the register
Read/Write
number.
Read/write
Data is 2 bytes and so is stored in "H00".
The lowest 1 byte can be referred to for the error code.
(For details on error codes, refer to the Instruction Manual
(Detailed) of the inverter.)
The faults history is batch-cleared by writing to register
40501.