Mitsubishi Electric 800 Series Instruction Manual page 53

Rs-485 interface board, rs-485 communication terminals
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Read/
Instruction
Item
write
Read
H6C
Second parameter
changing
(instruction code
HFF = 1, 9)
Write
HEC
Write/
Multi command
HF0
Read
Inverter
Read
H7C
model
Capacity
Read
H7D

Refer to
page 36

Turning OFF the power supply while clearing parameters with H5A5A or H55AA returns the communication parameter settings to the
initial settings.

Refer to the following calibration parameters list for details on the calibration parameters.

The gain frequency can be also written using Pr.125 (instruction code: H99) or Pr.126 (instruction code: H9A).
52
PARAMETER
code
When setting the calibration parameters
H00: Frequency

H01: Parameter-set analog value
H02: Analog value input from terminal
Available for writing 2 commands, and monitoring 2 items for reading data (Refer to
page
57.)
Reading inverter model in ASCII code.
"H20" (blank code) is set for blank area
Example of "FR-A840-E1 (FM type)"
H46, H52, H2D, H41, H38, H34, H30, H2D, H45, H31, H20, H20......H20
Reading inverter ND rated capacity in ASCII code.
Data is read in increments of 0.1 kW, and rounds down to 0.01 kW increments
"H20" (blank code) is set for blank area
Example
0.75K......"7" (H20, H20, H20, H20, H20, H37)
for data formats (A, A1, A2, B, C, C1, D, E, E1, E2, E3, F)
Data description

Number of
data digits
(Format)

2 digits
(B.E1/D)
2 digits
(A1,C/D)
10 digits
(A2,C1/D)
20 digits
(B,E3/D)
6 digits
(B,E2/D)