Item
No.
06
Routing ABB Table Setup
Use this option to define which part of the
ABB Table set up in Program 13-04 the sys-
tem will use for ANI/DNIS Caller ID
look-ups and ANI/DNIS routing.
This is required if Items 4 and 5 above are 1
(Caller ID on). When you specify a starting
and end address, the system uses the part of
the table for look-ups.
When you specify a starting address and
length, the system uses that part of the table
for routing. If the incoming ANI/DNIS num-
ber data matches the Number entry in the
table, the system routes according to the
associated Name data. That data can be an
extension, Department Group pilot number,
the voice mail master number or a trunk ring
group.
07
Routing on ANI/DNIS Error
This option lets you determine how the sys-
tem will handle an ANI/DNIS call if a data
error is detected in the incoming data string.
08
Routing When Destination Busy or No
Answer
This option lets you determine how the sys-
tem will handle an ANI/DNIS call if destina-
tion is busy or does not answer.
09
Calling Number Address Length
When Item 1=0 (ANI/DNIS receive format
is address), use this option to specify the
address length. The choises are from 1 to 8
digits in length.
Conditions
Feature Cross Reference
Aspila EX Software Manual
Name
None
Tie Lines
Program 34 : Tie Line Setup
34-09 : ANI/DNIS Service Options
Input Data
COS 01-14
Start = 0,
Start = 1000
100-1900
End = 1199
End = 0, 99-1999
0 = Play busy tone
to caller
1 = Route the
caller to the ring
group specified in
Program 25-03
0 = Play busy or
ringback tone to
caller
1 = Route the
caller to the ring
group specified in
Program 25-04
1-8
Default
COS 15
Start = 0
End = 0
1
0
0
0
7
7
Programming
Related
Program
13-04
25-03
25-04
34-09-01