Samsung OfficeServ 7100 Technical Manual page 67

Hide thumbs Also See for OfficeServ 7100:
Table of Contents

Advertisement

OfficeServ 7100
TECHNICAL MANUAL
3
External
Page Equipment
6
(600 ohms)
Figure 7.18 Connecting External/Additional Page Equipment
Dry Contact
Dry Contact is a switch that can connect or cut the power or line to external
equipment.
7.2.3 Loud Bell Interface
When a station requires loud ringing, assign or pair that station to an audible ring tone
output on the MISC port using MMC 205. Relay type can be assigned to Loud Bell in
MMC 218.
FUNCTION # in MMC 724
Next connect the output MISC port to a customer provided paging system or other
suitable customer provided speaker,
7.2.4 Connecting Common Bell
A customer-provided loud ringing device can be controlled using a dry contact pair on
the MP10 MISC port.
Common bell connections should be wired to the MP10 MISC port.
By using MMC 204 programming allows for interrupted or continuous operation of the
contacts. The interrupted selection follows the CO ring cadence, 1 sec ON/3 sec OFF.
Relay type can be assigned to Common Bell in MMC 218.
FUNCTION # in MMC 724
8
7
6
5
4
3
2
1
8 Conductor
Plug
MISC
03~04
see Figure 7.18.
MISC
03 or 04
7.15
Home Page
PART 7 APRIL 2007
Dry Contact
7
8
5
4
1
MOH/BGM
2
Dry Contact
DEFAULT
DN
362 or 363
DEFAULT
DN
362 or 363