3.2.1 Setting Switches
On the MP10 set the switches for the required configuration. The description for the
settings is described below.
• Memory Backup Switch (S1): When set to ON, all system programming is saved in
SRAM even when system is rebooted or powered OFF. This will be saved in SRAM
until the Super Capacitor has been drained of all charge (this charge will last only
up to 24 hours with system power OFF). At that point all programming will be lost. It
is recommended that all programming is saved to the MMC+ card or to a PC using
the OfficeServ Installation Tool application. Turning the switch (S1) OFF will set the
system to DEFAULT. To default the system, keep this switch (S1) in the OFF
position for 30 seconds. Switch to ON position before powering up the system.
Note: The S2 dip switches are set properly by the factory for a 3 digit numbering
plan and the country of USA. These dip switches should be left at default and
should never be changed. If a 4 digit numbering plan is required the numbering
plan should be changed in the software by using MMC 724.
ON (left)
4 DIGIT STATION NUMBERS
4 DIGIT STATION GROUPS
4 DIGIT TRUNK NUMBERS
COUNTRY SELECT
COUNTRY SELECT
COUNTRY SELECT
COUNTRY SELECT
Figure 3.2 Switch Setting
DIP SWITCH USE (S2)
SW8
SW7
SW6
RESERVED
SW5
SW4
SW3
SW2
SW 1
3.3
Home Page
PART 3 APRIL 2007
On
Off
S1
Off
On
OFF (right)
3 DIGIT STATION NUMBERS
3 DIGIT STATION GROUPS
3 DIGIT TRUNK NUMBERS
RESERVED
COUNTRY SELECT
COUNTRY SELECT
COUNTRY SELECT
COUNTRY SELECT