10. Change remaining system programming (see below) as required.
11. In order for the CTA adapter to recognized correctly, before plugging in the keyset, make sure that
12. Plug the line cord back into the keyset. This should only be done once the system has been pro-
13. Wait approximately 1 minute for the adapter to be recognized by the system.
14. Check Program 10-03-04 or 10-03-06 to make sure the system recognizes the CTA adapter. If not,
15. Install the CTA Adapter driver (downloaded from the NEC Technical Support web site
16. Connect the serial cable from the PC to the CTA Adapter.
System Programming
SMDR
System Alarms
4-42 ◆ Section 4: Telephones and Optional Equipment
Hook the two plastic prongs into the bottom of the phone.
Push the connector into place. The latch on the top of the adapter should lock into place when it is
properly positioned.
Connect an RS-232C straight-thru cable from the adapter to the printer or PC.
Change system programming (15-02-19) to match the CTA module dip switch settings.
Change system programming (15-02-20) to the correct baud rate.
in Program 10-03-01, the extension number using the adapter is undefined.
grammed as indicated in steps 8-10 above.
To avoid any hardware problems, when removing the adapter, first unplug the line cord, then
the power cord, then any other adapter cables.
unplug the phone, undefine the port in Program 10-03-01 and repeat the installation steps.
(http://ws1.necii.com).
Program 14-01-06 : Basic Trunk Data Setup - SMDR Print Out
Use this option to have the system include/exclude the trunk you are programming form the
SMDR printout. See Program 35-01 and 35-02 for SMDR printout options (0=No print out,
1=Prints out).
Program 15-02-19 : Multi-Line Telephone Basic Data Setup - CTA Data Communication Mode
Select '0' if the dip switch settings are set to PC connection or select '1' if printer/SMDR con-
nection is selected on the CTA adapter.
Program 15-02-20 : Multi-Line Telephone Basic Data Setup - Baud Rate for CTA Port
Set the baud rate to be used by the CTA (0=4800, 1=9600, 2=19200).
Program 35-01-01 : SMDR Options - Output Port Type
This option specifies the type of connection used for SMDR (0=No setting, 1=COM
(NTCPU), 2=USB (NTCPU), 4=CTA/CTU).
Program 35-01-02 : SMDR Options - Output Destination Number
This option specifies the extension number which has the CTA/CTU installed for the SMDR
printer output.
Refer to Section 5: Data and SMDR and the Aspire Software Manual (P/N 0893200) for
additional details on programming for SMDR.
Program 90-12-01 : System Alarm Output - Output Port Type
Define the output port to be used as the output for system alarm report (0=no setting,
1=NTCPU COM port, 2=NTCPU USB port, 4=CTA/CTU adapter). Set the baud rate for the
COM port in Program 10-21-02. The system can have up to 50 reports.
Program 90-12-02 : System Alarm Output - Destination Extension Number
If the output port type (90-12-01) is a CTA, enter the extension number with the CTA connection.